100 Amp 3 Phase Copper Wire Size: Comprehensive Guide

By

When it comes to three-phase electrical systems, choosing the right copper wire size is crucial. One common requirement is a 100 amp 3 phase circuit, which involves careful consideration of wire gauge, ampacity, and other factors to ensure safety and efficiency. This guide delves into the intricacies of selecting the appropriate copper wire size for a 100 amp 3 phase system.

The first step in determining the right copper wire size is understanding the specific details of your 100 amp 3 phase circuit. This includes the voltage level, the total length of the wire run, the ambient temperature, and any potential future loads. With these details in mind, you can calculate the wire size needed to safely and effectively carry the required electrical current.

Copper Wire Gauge and Ampacity

The gauge of a copper wire refers to its diameter, with larger wires having smaller gauge numbers. This is an essential factor in determining the wire's ampacity, which is the maximum current it can safely carry. For a 100 amp 3 phase circuit, you need to choose a copper wire gauge with an ampacity rating that can handle the total load, which is three times the phase current (since three phases are combined).

What Size of Wire Do I Need for a 100 Amp Sub Panel?
What Size of Wire Do I Need for a 100 Amp Sub Panel?
the different types of electrical wires are labeled in this diagram, which is what they look like
the different types of electrical wires are labeled in this diagram, which is what they look like
the size and length of wires are shown in this graphic above which wire sizes do you need to use?
the size and length of wires are shown in this graphic above which wire sizes do you need to use?

At 480V, the maximum current for one phase is approximately 105 amps (using Ohm's law). Therefore, for a 100 amp 3 phase circuit, the total load would be around 3 x 105 = 315 amps. Thus, you would need a copper wire with an ampacity of at least 315 amps for a 100 amp 3 phase service.

Wire Gauge for 100 Amp 3 Phase Circuit

Based on the ampacity requirement, let's identify suitable copper wire gauges for a 100 amp 3 phase circuit. As a starting point, consider that a typical 4/0 AWG (American Wire Gauge) copper wire can handle around 200 amps at 75 degrees Celsius. This gauge might initially seem suitable, but it's essential to consider other factors, such as voltage drop and derating rules.

an electrical calculator with the text how to calculate cable size mm2 for 3 phase
an electrical calculator with the text how to calculate cable size mm2 for 3 phase
the cable size chart for an electrical device, with different colors and sizes to choose from
the cable size chart for an electrical device, with different colors and sizes to choose from
an image of the table with numbers and times for different types of cable cables in it
an image of the table with numbers and times for different types of cable cables in it

For 480V systems, the wire should not experience more than a 3% voltage drop under full load. If the length of your wire run results in a higher voltage drop, you may need to use a larger gauge wire. Additionally, derating factors account for variables like ambient temperature, conduit fill, and bundling. Applying these derating factors may require using a larger wire gauge than initially calculated.

Conduit Size and Wire Filling

Copper wire size is closely related to the conduit size, as wires fill the conduit and must leave enough space for future grounds and neutrals. For a 100 amp 3 phase circuit, you'll typically use a 350 MCM or 500 MCM copper cable, which fills conduits according to the following table:

Copper Wire Size (AWG)Conduit Size (MCM)Wires per Conduit
4/03504
2505006

For example, using a 4/0 copper wire in a 350 MCM conduit allows for four wires in total, leaving room for future grounds and neutrals. Keep in mind that conduit fill percentage also affects wire ampacity, so ensure you're not overfilling the conduit to maintain the safe ampacity of your copper wires.

Copper Wire Size Chart awg/swg: All You need to Know in mm or Inches
Copper Wire Size Chart awg/swg: All You need to Know in mm or Inches
an electrical panel with multiple wires attached to it
an electrical panel with multiple wires attached to it
the industrial cable size chart is shown
the industrial cable size chart is shown
four different types of electrical wires on a blue background with the numbers 1, 3, and 5
four different types of electrical wires on a blue background with the numbers 1, 3, and 5
3-Phase Cable Size Calculation – Practical Engineering Approach (11 kV / LV Industrial Feeders) This example shows a complete, standards-based method to select power cables for a 365 kW 3-phase load… | Amir Sohail . PE Eng
3-Phase Cable Size Calculation – Practical Engineering Approach (11 kV / LV Industrial Feeders) This example shows a complete, standards-based method to select power cables for a 365 kW 3-phase load… | Amir Sohail . PE Eng
three phase, single phase, motor cable size selection chart for the different types of cables
three phase, single phase, motor cable size selection chart for the different types of cables

NEC and Code Compliance

The National Electrical Code (NEC) sets the standards for safe electrical practices in the United States. When selecting a copper wire size for a 100 amp 3 phase circuit, it's crucial to comply with the NEC and local electrical codes. Consult the NEC tables and your local electrical inspector to ensure your chosen wire size meets all regulations and safety requirements.

Proper design and installation of a 100 amp 3 phase system involves more than just selecting the right copper wire size. Considerations such as overcurrent protection, grounding, and equipment ratings must also be addressed to maintain a safe and reliable electrical system. Always consult with a licensed electrician or electrical engineer to ensure your project's compliance with NEC and local codes.

Wire Type and Stranding

When selecting a copper wire for a 100 amp 3 phase circuit, consider the wire type and stranding. Generally, you'll want to use a copper flexible steel armored cable (FSC) or a copper portable cord for equipment hookups. For fixed wiring, non-metallic sheathed (NM) cable or metallic armored cable (AC) can be used, depending on the specific application and local codes.

Electrical wire size & load conversation chart
Electrical wire size & load conversation chart
Bare Pure Copper Wire Diameter 0.3 0.4 0.5 0.6 0.7 0.8 1 1.2 1.4 1.5 1.6 1.8 2 2.5mm High
Bare Pure Copper Wire Diameter 0.3 0.4 0.5 0.6 0.7 0.8 1 1.2 1.4 1.5 1.6 1.8 2 2.5mm High

Stranding, or the way the copper wires are twisted together, affects the wire's flexibility and resistance to movement. For most applications, a standard stranded copper wire will suffice. However, when wiring is exposed to vibration or frequent movement, using a clenched (served) or/core strand wire can help improve durability and longevity.

Properly selecting a copper wire size for a 100 amp 3 phase circuit is essential for ensuring the safety, efficiency, and longevity of your electrical system. By understanding the specific requirements of your application, applying sound electrical engineering principles, and adhering to NEC and local codes, you can choose the right copper wire size for your project. Don't hesitate to consult with a professional electrician or electrical engineer to ensure your project's success and compliance with electrical standards.