100 Amp Aluminum Wire Size for Sub Panel: Gauge & Size Chart

By

When it comes to wiring a subpanel, choosing the correct wire size is paramount for safety and efficiency. One common question is about using 100 amp aluminum wire for a subpanel. Let's dive into the details to help you make an informed decision.

Aluminum wire is a popular choice due to its cost-effectiveness and non-corrosive nature. However, it's crucial to understand its specific size and gauges to ensure it meets your electrical needs and follows local electrical codes.

Understanding Wire Gauge & Current Rating

The American Wire Gauge (AWG) system is used to measure the size of electrical wire. The larger the gauge number, the smaller the wire diameter. Current rating, on the other hand, indicates the maximum amount of current a wire can safely carry.

What Size of Wire Do I Need for a 100 Amp Sub Panel?
What Size of Wire Do I Need for a 100 Amp Sub Panel?
What is the Right Wire Size for 100-Amp Service Panel?
What is the Right Wire Size for 100-Amp Service Panel?
What Size Aluminum Wire for 125 Amp Service?
What Size Aluminum Wire for 125 Amp Service?

In this case, understanding that a 100 amp wire can handle 100 amps of current is straightforward. However, the associated gauge might not be as obvious. The gauge of a 100 amp aluminum wire is typically #4 AWG.

Why #4 AWG Aluminum Wire for a 100 Amp Subpanel?

Aluminum wire's current-carrying capacity (CCC) is lower than that of copper due to its conductance difference. Therefore, a #4 AWG aluminum wire is needed to handle 100 amps of current. Here's a quick comparison:

Wire Size For 100 Amp Service 150 Feet
Wire Size For 100 Amp Service 150 Feet
What wire type & size for sub-panel in a shed?
What wire type & size for sub-panel in a shed?
How to Wire a Subpanel? Main Lug Installation for 120V/240V
How to Wire a Subpanel? Main Lug Installation for 120V/240V
  • Copper: A #2 AWG copper wire can handle 100 amps.
  • Aluminum: A #4 AWG aluminum wire is required for the same current rating.

Electrical Code Requirements for Aluminum Wiring

In the United States, the National Electrical Code (NEC) requires that aluminum wire be used with aluminum connectors or approved connectors listed for aluminum. This is due to varying expansion rates between aluminum and copper, which can lead to improper connections over time.

Moreover, aluminum wire must be sized according to the ampacity requirements of the wire type. For #4 AWG aluminum, this means it must be used in applications where a 100 amp circuit is required.

Sizing the Subpanel for 100 Amp Aluminum Wire

Now that we understand the wire size and requirements, let's discuss the subpanel itself. A subpanel's main breaker size should match your selected main feed wire size.

What Size of Wire for 30 Amp?
What Size of Wire for 30 Amp?
100 amp Attached Garage Sub Plan
100 amp Attached Garage Sub Plan
How to Wire a Subpanel? Main Lug Installation for 120V/240V
How to Wire a Subpanel? Main Lug Installation for 120V/240V
an electrical panel with wires connected to subpannel and ground busbars labeled
an electrical panel with wires connected to subpannel and ground busbars labeled
240v Sub Panel Wiring Diagram
240v Sub Panel Wiring Diagram
an electrical panel with the words, 100 amp sub panel install and instructions on it
an electrical panel with the words, 100 amp sub panel install and instructions on it

Since you're using 100 amp aluminum wire, your subpanel should also have a 100 amp main breaker. This ensures that the subpanel can safely handle the current supplied to it. Here's an overview:

  • 100 amp aluminum wire (#4 AWG) for the main feed.
  • A 100 amp main breaker in the subpanel.
  • Circuit breakers in the subpanel rated for the specific circuit needs (e.g., 20 amp, 30 amp, etc.).

Choosing the Right Subpanel Enclosure

Selecting the correct subpanel enclosure is as important as choosing the right wire and breaker sizes. The enclosure should be rated for the main breaker's amp rating, in this case, 100 amp. Additionally, it should suit your installation environment, whether indoor or outdoor, and protect against external factors like moisture and dust.

Common subpanel enclosures include NEMA 1 (general-purpose indoors) and NEMA 3R (general-purpose indoors/outdoors). Always check local codes and manufacturer recommendations for the best fit.

an electrical wiring diagram with two different types of wires and the main parts in it
an electrical wiring diagram with two different types of wires and the main parts in it

In summary, using 100 amp aluminum wire (#4 AWG) for a subpanel requires careful planning and adherence to electrical codes. By understanding wire gauges, amperage, and ensuring your subpanel and connections are compatible, you can create a safe and efficient electrical setup. Don't hesitate to consult a professional electrician if you're unsure about any aspect of the process.