Convert 14 SWG to AWG: Essential Gauge Conversion Chart

By

Ever found yourself scouring charts and conversion tables to understand the difference between SWG and AWG? You're not alone. While both terms are essential for those working with wires and cables, the two standards often cause confusion due to their differing origins. Let's dive into the world of stranded and regular wires, and clear up the difference between 14 SWG and AWG.

Our journey begins with the fundamental difference: **SWG (Wire Gauge) vs. AWG (American Wire Gauge)**. SWG is used predominantly in the UK and other Commonwealth nations, while AWG is the standard in the United States. They represent different aspects of a wire:SWG focuses on the wire's diameter, while AWG considers the cross-sectional area of the wire. Now, let's explore each in more detail.

Understanding SWG

The SWG standard originated in the UK and is still widely used today. It's based on a simple formula: the numerical SWG value determines the wire's diameter in inches. Thus, **a higher SWG number indicates a smaller wire**.

14AWG 4-Core Shielded CNC Wire Guide
14AWG 4-Core Shielded CNC Wire Guide
Stranded Wire Chart (AWG)
Stranded Wire Chart (AWG)
what is 14/2 wire used for Archives - The Engineering Knowledge
what is 14/2 wire used for Archives - The Engineering Knowledge

Knowing this, you might think that understanding 14 SWG is easy. However, SWG doesn't account for the number of strands in a wire. If you're working with stranded wire, you'll need to use the **BS 4602 (British Standard)** for an accurate measurement.

SWG for Stranded Wire

BS 4602 provides a more comprehensive standard, accounting for both the wire's diameter and the number of strands. Using this standard, **14 SWG stranded wire will have 18 to 19 strands, each with a diameter of 0.241 mm**.

the table is shown with numbers and times for each item in this table, which shows the
the table is shown with numbers and times for each item in this table, which shows the
Campervan Wire Size And Fuses | VanLife Adventure
Campervan Wire Size And Fuses | VanLife Adventure
how to find the right wire size for 100 amp in awg
how to find the right wire size for 100 amp in awg

A quick glance at the table below will help you understand the relationship between SWG and the number of strands officially recognized by the BS 4602 standard.

BS 4602 - SWG vs. Strand Count
SWGNumber of StrandsStrand Diameter (mm)
1418-190.241
1626-280.184
1837-400.134

SWG vs. AWG: A Brief Comparison

Now that we understand SWG, let's compare it briefly with AWG. To do this, we'll use the **AWG to SWG conversion formula**: AWG = (36 - 2 * SWG) / 3. This formula helps us see that, **while both systems are numerical, they essentially move in opposite directions** (as SWG increases, AWG decreases).

The primary reason for this lies in their origins. AWG was developed in the United States, while SWG emerged in the British Empire. Hence, their standardization reflects each nation's unique electrical and industrial history.

Wire Gauge Chart: Amps & Common Household Uses
Wire Gauge Chart: Amps & Common Household Uses
Wire Gauge Chart | American Wire Gauge (AWG) Wire Size Chart
Wire Gauge Chart | American Wire Gauge (AWG) Wire Size Chart
the table shows how many different types of electrical equipment are available for each type of device
the table shows how many different types of electrical equipment are available for each type of device
AWG Size Chart Complete Guide
AWG Size Chart Complete Guide
Awg Sizes & Properties of Electrical Cables / Conductors Magnetic Chart 5.5\
Awg Sizes & Properties of Electrical Cables / Conductors Magnetic Chart 5.5\
AWG para mm²
AWG para mm²

Exploring AWG

Now that we've delved into the world of SWG let's turn our attention to **AWG (American Wire Gauge)**, the United States' prevailing standard. Unlike SWG, AWG considers the wire's cross-sectional area, not just the diameter. **Thus, a higher AWG number indicates a smaller wire**—an inverse relationship to SWG.

For instance, **14 AWG represents a wire with a cross-sectional area of approximately 2.094 square millimeters**. However, AWG doesn't provide information about stranded wire.

AWG for Stranded Wire

To determine the number of strands in stranded AWG wire, you'll need to use additional standards like **NEMA (National Electrical Manufacturers Association) or ASTM (American Society of Testing and Materials)**. These standards provide guidelines for strand count based on AWG size.

an image of the awg vs swg table with numbers and times on it
an image of the awg vs swg table with numbers and times on it
an old table with numbers and times for different types of people in the united states
an old table with numbers and times for different types of people in the united states
The AWG number is inversely proportional to the wire's size.
The AWG number is inversely proportional to the wire's size.

For example, according to **NEMA WC 5/53-1986**, **14 AWG stranded wire should have 19 to 21 strands, each with a diameter of approximately 0.323 mm**.

The table below offers a glimpse into the relationship between AWG, cross-sectional area, and strand count according to NEMA and ASTM standards.

AWG vs. Cross-Sectional Area vs. Strand Count
AWGCross-Sectional Area (mm²)Number of Strands (NEMA / ASTM)Strand Diameter (mm)
142.09419-21 (NEMA) 20-22 (ASTM)0.323
161.32026-28 (NEMA) 27-30 (ASTM)0.218
180.82439-42 (NEMA) 41-45 (ASTM)0.146

The Impact of Stranding on Wire Gauge

Now that we know the essentials of SWG and AWG, let's briefly discuss the impact of stranding on wire gauge. Stranding refers to creating a wire from multiple, thinner strands rather than a single, solid core. This process offers several benefits, including **improved flexibility, better conductivity, and reduced resistance to bending**.

Whereas **solid wire is typically stronger and more rigid, stranded wire is more flexible and resistant to damage**. However, it's essential to remember that **stranding can affect a wire's overall gauge**, as seen in the BS 4602 and NEMA standards.

In conclusion, understanding the difference between 14 SWG and AWG requires familiarity with both standards. SWG, primarily used in the UK, focuses on wire diameter, while AWG, prevalent in the United States, considers the wire's cross-sectional area. Stranding further complicates matters, as it may necessitate additional standards, such as BS 4602, NEMA, or ASTM. However, with this knowledge, you're equipped to navigate the world of wires and cables with confidence. Happy manufacturing!