3 Phase 100 Amp Wire Sizes: Complete Guide

By

When it comes to electrical wiring, understanding the correct gauge or size of the wire is crucial. This is especially true for three-phase 100 amp circuits, where the size of the wire must be proper to handle the expected load. So, what is the wire size for a 100 amp three-phase circuit?

In the United States, the National Electrical Code (NEC) dictates that a 100 ampere three-phase circuit should use a minimum of no. 6 American Wire Gauge (AWG) for the conductors. This ensures that the wire can safely handle the expected load without overheating. However, it's essential to understand that the wire size also depends on the type of conductor material and the length of the run.

The(Thread) Theory Behind Ampacity

The NEC bases wire sizing on a concept known as ampacity. Ampacity is the current-carrying capacity of an electrical conductor, taking into account factors like conductor size, type of insulation, ambient temperature, and the number of conductors in a bundle (or thread).

What Size of Wire for 30 Amp?
What Size of Wire for 30 Amp?
208v 120v 240v, 208v 120v 240v Panel Wiring Diagram, 208v 120v 240v Wiring Diagram, High Leg Delta Wiring Diagram, How To Wire A 208v Panel, How To Wire A 3 Phase Delta Connection, 3 Phase Panel Wiring, Three-phase Wiring Guide, 1-phase 3-phase Wiring Guide
208v 120v 240v, 208v 120v 240v Panel Wiring Diagram, 208v 120v 240v Wiring Diagram, High Leg Delta Wiring Diagram, How To Wire A 208v Panel, How To Wire A 3 Phase Delta Connection, 3 Phase Panel Wiring, Three-phase Wiring Guide, 1-phase 3-phase Wiring Guide
wiring diagram for the vac three - wire plus ground line and other electrical equipment
wiring diagram for the vac three - wire plus ground line and other electrical equipment

In the case of a 100 amp three-phase circuit, each phase is responsible for carrying about 33.3 amps (100 amps / 3 phases). So, a no. 6 AWG copper conductor has an ampacity of 65 amps, giving a significant safety margin for the 33.3 amps that each phase will carry.

Conductor Material and Ampacity

While copper is a commonly used conductor for its high ampacity, other materials like aluminum or copper-clad aluminum can also be used. However, it's crucial to note that their ampacity is lower than that of copper. For instance, a no. 6 AWG aluminum conductor has an ampacity of 50 amps, which might not provide an adequate safety margin for a 100 amp three-phase circuit.

What is the Right Wire Size for 100-Amp Service Panel?
What is the Right Wire Size for 100-Amp Service Panel?
What Size Wire for 50 Amp? Exact Gauge Guide for Safe & Code-Compliant Wiring
What Size Wire for 50 Amp? Exact Gauge Guide for Safe & Code-Compliant Wiring
How to wire 3-phase
How to wire 3-phase

Moreover, NEC requires different derating factors for different conductor materials. Copper and copper-clad aluminum conductors have a derating factor of 1.25, while aluminum conductors have a derating factor of 0.9. Thus, even if the ampacity allows, aluminum conductors will compulsory require a larger size compared to copper.

Length of the Run and Temperature Correction Factors

Beyond the conductor's material and size, the length of the run also impacts wire size. Longer runs can result in significant voltage drops, so a larger wire might be needed to minimize this drop. A Wire Sizing Table or localité software can be used to determine the required wire size based on the specific run's length.

Additionally, temperature correction factors must be applied if the ambient temperature exceeds 86°F (30°C). When the ambient temperature is higher, a larger wire size might be necessary to prevent the wire from overheating. The NEC provides correction factors for various temperatures, which should be applied when sizing the wire.

Three Phase Wiring
Three Phase Wiring
the table shows how many different types of voltages are used to power an electrical device
the table shows how many different types of voltages are used to power an electrical device
456K views · 4.3K reactions | 3 Phase to single phase Motor Connection.... #DPElecctronic #Electrical #Elecctronic #fblifestyle #instagramreels #interiordesign #electricalwrok #DPElecctronicfollow | 𝐃𝐏 𝐄𝐥𝐞𝐜𝐜𝐭𝐫𝐨𝐧𝐢𝐜
456K views · 4.3K reactions | 3 Phase to single phase Motor Connection.... #DPElecctronic #Electrical #Elecctronic #fblifestyle #instagramreels #interiordesign #electricalwrok #DPElecctronicfollow | 𝐃𝐏 𝐄𝐥𝐞𝐜𝐜𝐭𝐫𝐨𝐧𝐢𝐜
Electrical wire size & load conversation chart
Electrical wire size & load conversation chart
an electrical calculator with the text how to calculate cable size mm2 for 3 phase
an electrical calculator with the text how to calculate cable size mm2 for 3 phase
70 Amp Wire Size: Breaker & Wiring Gauge Guide
70 Amp Wire Size: Breaker & Wiring Gauge Guide

NEC Requirements for Three-Phase 100 Amp Circuits

The NEC provides clear guidelines for sizing and installing conductors in three-phase 100 amp circuits. For example, it requires that the conductors be clearly identified by phase labeling or color-coding, and that they be installed in a manner that maintains their original size and shape.

Moreover, it stipulates that 100 amp circuits must include overcurrent protection devices, such as circuit breakers or fuses, to prevent the circuit from drawing more current than it can safely handle.

Conductor Sizing Tables

NEC provides conductor sizing tables in Article 310 to simplify the process of selecting the correct wire size for a given current and maximum loading. These tables consider many factors, including conductor material, insulation type, and ambient temperature.

How to Connect a 3 Phase Motor to a Single Phase Power at Home #motor #motors #motorcapacitors
How to Connect a 3 Phase Motor to a Single Phase Power at Home #motor #motors #motorcapacitors

For instance, referring to Table 310.16, a 100 amp three-phase circuit with copper conductors rated for 90°C, and no more than three current-carrying conductors in the raceway or cable, requires at least a no. 4 AWG copper conductor.

Locality Software

While NEC tables provide a good starting point, they can be complex and challenging to navigate for those not familiar with them. Locality software, like 'Hagerocity' or 'Elexo', can simplify the process. They consider all relevant factors, such as voltage drop, harmonics, and NEC requirements, to calculate the optimal wire size for a specific circuit.

For instance, using Hagerocity for a 100 amp three-phase circuit with copper conductors, standard conduit fill, and a voltage drop of 3%, it recommends a no. 4 AWG copper conductor for a 100 ft run.

Choosing the correct wire size for a 100 amp three-phase circuit is critical to ensure the circuit's safety and efficiency. It's always a good idea to consult with a professional electrician or use locality software to ensure you're following NEC guidelines and best practices. Ultimately, investing in the right wire size can save you time, money, and potential safety hazards in the long run.