Armoured Cable Cleat Size Chart

By

In the realm of electrical engineering, the selection of appropriate cable management solutions is vital to ensure safety, efficiency, and longevity of electrical systems. One critical component in this process is the use of armoured cable cleats, which secure and support cables while providing mechanical protection. To make the right choice, it's essential to understand the armoured cable cleat size chart, which we will delve into in this comprehensive guide.

The armoured cable cleat size chart is a crucial reference for electrical engineers, installers, and technicians. It helps determine the appropriate cleat size based on the cable's outer diameter, armoured outer diameter, or current rating. Understanding this chart not only ensures correct installation but also plays a significant role in preventing potential hazards such as cable damaged or catastrophic failures.

Understanding Armoured Cable Sizes

Before exploring the size chart, it's crucial to be familiar with the armouring types and cable sizes. Armoured cables can be metallic (steel tape or wire) or non-metallic (fibreglass, (PVC), or neoprene). Sizes are typically expressed as the cable's outer diameter, measured in millimetres (mm), or its current rating in Amperes (A).

758K views • 7.6K likes | Reel by Maa Khodal Electrician
758K views • 7.6K likes | Reel by Maa Khodal Electrician
Electrical Wire & Cable Sizes with Current Rating ⚡ Cheat Sheet for Safe Wiring Guide
Electrical Wire & Cable Sizes with Current Rating ⚡ Cheat Sheet for Safe Wiring Guide
Specialised Wiring Accessories
Specialised Wiring Accessories

For example, a cable marked as 10mm² indicates that its cross-section is 10 square millimeters, while a 35mm² indicates 35 square millimeters. The current rating, meanwhile, is influenced by the conductor size, insulation, and armour. For instance, a cable rated at 16A can carry up to 16 Amperes of electrical current.

Armour Types and Their Associated Cleats

Metal tape armoured cables require separate armour molex connectors to secure and support both the cable and armour. The connectors come in various sizes, typically ranging from 35mm² to 120mm². Cleats for steel wire armoured cables, on the other hand, usually accord with cable sizes, from 35mm² to 185mm², with special considerations for larger diameters or high current ratings.

What is a Cable Length? | The meaning
What is a Cable Length? | The meaning
table size chart for cable sizes
table size chart for cable sizes
Cable Gland Chart: A Guide for Electrical Design | Gurunath Tatphale posted on the topic | LinkedIn
Cable Gland Chart: A Guide for Electrical Design | Gurunath Tatphale posted on the topic | LinkedIn

Non-metallic armour, such as neoprene or PVC, requires different cleats, often made of plastic for corrosion resistance. These cleats typically accommodate cable sizes from 10mm² to 160mm², with special consideration for high flexibility and UV resistance.

Director and Lateral Cleats

Director cleats are used to secure cables running in straight lines, acting as cable saddle and support. They come in various sizes based on the cable's outer diameter and armour type. Lateral cleats, meanwhile, are designed to secure cables where two runs intersect or crossover, preventing cable kinking or chafing. Both types have specific size charts based on cable dimensions.

For instance, a lateral cleat for a 10mm² PVC armoured cable would be different from one designed for a 160mm² steel wire armoured cable. Careful consideration of the size chart is vital to avoid under- or over-sized cleats, which can lead to improper support and damage to the cable or cleat.

the table shows the number and type of electrical codes for various types of installations
the table shows the number and type of electrical codes for various types of installations
Cable Size Selection
Cable Size Selection
Cable Size Calculation for LT & HT Motors | Electrical Technology
Cable Size Calculation for LT & HT Motors | Electrical Technology
the table shows how many different cable sizes are available
the table shows how many different cable sizes are available
the cable size selection is shown with different types of wires and wire sizes on it
the cable size selection is shown with different types of wires and wire sizes on it
the cable size guide for cables and gland sizes is shown in this image
the cable size guide for cables and gland sizes is shown in this image

Interpreting the Armoured Cable Cleat Size Chart

Armoured cable cleat size charts often display armour type in one column, cable dimension (outer diameter or current rating) in another, and corresponding cleat size in another. For example:

Armor Type Cable Diameter (mm) / Current Rating (A) Cleat Size
Steel Wire 10mm² / 16A S6
Steel Wire 35mm² / 24A M12

This chart indicates that for a steel wire armoured cable with an outer diameter of 10mm and a current rating of 16A, an S6 cleat should be used. Similarly, for a 35mm² steel wire armoured cable with a 24A current rating, an M12 cleat is required.

Size charts may also categorize cleats by their span-range, indicating the maximum distance between cleats based on cable size. This is crucial for maintaining adequate cable support and preventing sagging.

Cable Lug Size List
Cable Lug Size List
Cable Cleat Installation guide
Cable Cleat Installation guide

Special Considerations

When using the size chart, there are special considerations that may require cleats of a different size to be used:

  • Cable Bunching: When multiple cables are installed together, or 'bunched,' larger cleats are required to accommodate the increased diameter.
  • Cable Conduits: Cables installed within conduits may require smaller cleats, as the conduit reduces the cable's effective outer diameter.
  • Cable Current Rating: Cables with higher current ratings may require larger cleats, even if the cable's outer diameter falls within the nominal range of a smaller cleat, to accommodate the increased heating and potential cable expansion.

Properly understanding and applying the armoured cable cleat size chart ensures optimal cable management, enhanced safety, and longevity of your electrical systems. Regular inspection and maintenance of your cleats is also crucial to identify and rectify any potential issues early, enhancing overall system reliability.

As we’ve seen, the armoured cable cleat size chart is more than just a technical reference. It's a critical tool that enables safe, efficient, and reliable electrical installations. By understanding and applying the chart correctly, electrical engineers, installers, and technicians can ensure their electrical systems are protected and perform as expected. Understanding the size chart is the first step towards enhanced electrical system performance and longevity. So, why not get started today?