Armoured Cable Sizes & Current Carrying Capacity: Comprehensive Table

By

Choosing the right armored cable size and understanding its current carrying capacity is paramount for ensuring optimal performance, safety, and longevity in electrical systems. This comprehensive guide will help you navigate the intricacies of armored cable sizes and their current carrying capacities, empowering you to make informed decisions.

Armored cables, often used in industrial and commercial settings, offer mechanical protection and are essential for safe, reliable electrical power transmission. Their insulated conductors are encased in corrugated metallic sheaths, such as steel wire armor or lead sheathing, providing resistance against physical damage, moisture, and chemical corrosion.

Understanding Armored Cable Sizes

Armored cable sizes are typically designated by their outer sheath dimensions rather than the cross-sectional area of their conductors, as is the case with unarmored cables. The most common method for identifying a cable's size is the British Standard (BS) or American Wire Gauge (AWG) system.

the table shows the number and type of electrical codes for various types of installations
the table shows the number and type of electrical codes for various types of installations
Cable Size Calculation for LT & HT Motors | Electrical Technology
Cable Size Calculation for LT & HT Motors | Electrical Technology
the cable size selection is shown with different types of wires and wire sizes on it
the cable size selection is shown with different types of wires and wire sizes on it

The size prefixes in armored cables usually consist of the letter 'S' followed by a number, e.g., 'S/SWA' or 'LS', where 'S' stands for "steel-wire armored", 'SWA' for "steel wire sheath", and 'LS' for "lead-sheathed". The number indicates the size or gauge of the cable, determined by the outer sheath's diameter.

British Standard (BS) Sizes

The BS system uses a numbering sequence that increases with cable size, e.g., BS 21.5, BS 25, BS 35, etc. The number denotes the cable's nominal size in millimeters, representing the diameter of the armor or the outer sheath.

table showing the current voltages for different types of wires
table showing the current voltages for different types of wires
Electrical Wire & Cable Sizes with Current Rating ⚡ Cheat Sheet for Safe Wiring Guide
Electrical Wire & Cable Sizes with Current Rating ⚡ Cheat Sheet for Safe Wiring Guide
IEC 60364 5 52 | Best Guide on Cable Sizing & Current Carrying Capacity
IEC 60364 5 52 | Best Guide on Cable Sizing & Current Carrying Capacity

Here's a simplified table highlighting some common BS sizes, their approximate cable diameters, and conductor sizes (in mm²) for a 3-core PVC insulated cable:

BS SizeApprox. Outer Diameter (mm)Conductor Size (mm²)
BS 21.514.51.5
BS 2517.52.5
BS 3523.55.0
BS 7035.516.0

American Wire Gauge (AWG) Sizes

The AWG system uses a reverse numbering sequence, meaning the gauge number decreases as the cable size increases. For example, a 14 AWG cable is smaller than an 18 AWG cable.

Here's a table demonstrating some common AWG sizes, their approximate outer diameters, and conductor sizes (in AWG and mm²):

the table shows the number and type of electrical equipment used in this project, as well as
the table shows the number and type of electrical equipment used in this project, as well as
Cable Sizing
Cable Sizing
the industrial cable size chart is shown
the industrial cable size chart is shown
Cable Size Selection
Cable Size Selection
the product information sheet for mega kabel products is shown in red, yellow and green
the product information sheet for mega kabel products is shown in red, yellow and green
Orbit
Orbit
AWG SizeApprox. Outer Diameter (mm)Conductor Size (AWG)Conductor Size (mm²)
14 AWG5.1141.63
12 AWG6.4123.30
10 AWG7.9105.27
8 AWG9.388.38

Current Carrying Capacity of Armored Cables

The current carrying capacity (CCC) of an armored cable depends on several factors, including the conductor size, insulation type, installation conditions, and environmental factors. These factors impact the cable's ability to dissipate heat, which is generated when electrical current flows through the conductor.

For the sake of this discussion, let's focus on the primary factor: the conductor's size. The following table provides a general indication of the CCC for both BS and AWG armored cable sizes at various temperatures and standard ambient conditions:

BS/AWG SizeConductor Size (mm²)CCC (A) @ 70°CCCC (A) @ 90°C
BS 21.51.51612
BS 252.52519
BS 355.04534
BS 7016.012594
14 AWG1.631511
12 AWG3.302217
10 AWG5.273225
8 AWG8.385542

For accurate and up-to-date information, always consult the manufacturer's datasheets or communicate with their technical support. They can provide tailored advice based on your specific installation requirements and conditions.

Standard Wire Gauge “SWG” Calculator - SWG Size Chart & Table
Standard Wire Gauge “SWG” Calculator - SWG Size Chart & Table

Understanding armored cable sizes and their current carrying capacities enables you to ensure optimal electrical performance, enhance safety, and minimize maintenance. Regularly reviewing your electrical systems' requirements and staying informed about advancements in cable technology will safeguard your operations and reduce unnecessary expenses.

Next steps? Evaluate your current electrical infrastructure, and contact an experienced electrical consultant or supplier to discuss any upgrades or changes necessary to meet your evolving power demands efficiently and safely.