▲Wirig Diagram Hot
▲ ▲ ▼

American Wire Gauge To Cable Diameter: Convert AWG To mm/inches

By

When discussing electrical cables, two key concepts often intertwine: American Wire Gauge (AWG) and cable diameter. Understanding the relationship between AWG and cable diameter is crucial for selecting the right cable for your electrical needs.

AWG, also known as Brown & Sharpe wire gauge, is a standard for measuring the diameter of a-round conductive wire. This system, developed in the 19th century, is widely used in the United States and other countries. On the other hand, cable diameter refers to the outer dimension of a cable, including its insulation and jacket.

Understanding AWG

The AWG system is based on a geometric progression, with larger AWG numbers representing smaller diameters. For example, a 12 AWG wire is thicker than a 16 AWG wire. The AWG is not only about the wire's size but also its conductivity and current-carrying capacity.

How to Convert Cable Size from AWG to Inches | InstrumentationTools
How to Convert Cable Size from AWG to Inches | InstrumentationTools
Kabel Cable AWG 22 4 Core per Meter
Kabel Cable AWG 22 4 Core per Meter
Calibres AWG de Cables
Calibres AWG de Cables

Here's a table showing the cross-sectional area and approximate diameter for various AWG sizes, providing a clearer picture of the relationship between AWG and diameter:

Wire Gauge Cross-sectional Area (mm²) Approximate Diameter (mm)
12 2.05 2.09
14 1.34 1.65
16 0.84 1.30
18 0.52 1.03

AWG and Current-carrying Capacity

The AWG also dictates a wire's current-carrying capacity. Generally, a larger AWG (like 12 or 10) can carry more current than a smaller AWG (like 18 or 20). This is because larger wires have more copper and thus better conductivity.

cable size
cable size
several different types of wires are shown in this diagram, with the corresponding colors and sizes
several different types of wires are shown in this diagram, with the corresponding colors and sizes
The AWG number is inversely proportional to the wire's size.
The AWG number is inversely proportional to the wire's size.

Here's a simple breakdown of current-carrying capacities for some common AWG sizes in a typical household (120V circuit):

  • 12 AWG: 20 amps
  • 14 AWG: 15 amps
  • 16 AWG: 13 amps
  • 18 AWG: 7.5 amps

AWG and Insulation

The AWG of an electrical wire might affect the thickness of its insulation, but the primary factor determining insulation thickness is the voltage rating of the wire. High voltage wires require thicker insulation, regardless of their AWG.

However, as a general rule, larger AWG wires often have slightly thicker insulation. This is because the larger wire's diameter necessitates more insulating material to maintain the electrical clearances.

MM2 to AWG - Wire Size Conversion Chart, Table, & Calculator [PDF]
MM2 to AWG - Wire Size Conversion Chart, Table, & Calculator [PDF]
Cables AWG Diferentes
Cables AWG Diferentes
Kabel AWG Silicone Serabut 6AWG, 7AWG, & 9AWG panjang 1 meter
Kabel AWG Silicone Serabut 6AWG, 7AWG, & 9AWG panjang 1 meter
three different types of electric motors are shown in this image, and there is an information sheet
three different types of electric motors are shown in this image, and there is an information sheet
AWG Size Chart Complete Guide
AWG Size Chart Complete Guide
Cord Length Matters
Cord Length Matters

AWG vs Cable Diameter

Now, let's discuss the relationship between AWG and cable diameter. The cable diameter, as previously mentioned, includes the wire itself plus its insulation and jacket. For a given AWG, the exact cable diameter can vary depending on the cable type, insulation material, and the manufacturer's specific design.

Here's a comparison of AWG sizes with their respective wire diameters and a simple, round-jacketed cable's typical outer diameter:

Wire Gauge Wire Diameter (mm) Cable Diameter (mm)
12 2.09 6-9
14 1.65 4-6
16 1.30 3-5
18 1.03 2.5-4

Cable Conductor, Insulation, and Jacket

The cable diameter also varies based on the cable's construction. Some cables may have multiple conductors (wires) twisted together, sharing one insulation layer. Others might have each conductor insulated individually, then bundled together with a final jacket.

table of awg wire gauge sizes
table of awg wire gauge sizes

These differences in construction can significantly impact the cable's overall diameter. For instance, a 14 AWG stranded cable with individual insulation might measure around 5.5 mm in diameter, while a 14 AWG, multi-conductor, flat cable could measure as little as 3 mm.

Voltage and Flexibility

For high voltage applications, cables often require significant insulation, contributing to their overall diameter. Additionally, flexible cables tend to have larger diameters to accommodate the necessary strain relief and movement.

For example, a 12 AWG, flexible, rubber jacketed cable might have a diameter of 10-12 mm, due to its necessary insulation and flexible construction.

In many cases, choosing the right cable involves balancing factors like AWG, outer diameter, current-carrying capacity, and insulation rating. Always consult local electrical codes and guidelines when selecting cables for a specific application.