▲Wirig Diagram Hot
▲ ▲ ▼

Awg vs MM2 vs Amp: Wire Size Showdown

By

When it comes to electrical units of measurement, you might have come across terms like AWG, MM2, and amp. While they might seem like alphabet soup, understanding these units is crucial for selecting the right wire, cable, or electrical component for your application. Let's dive into the world of AWG, MM2, and amp, and explore how they differ from one another.

In electronics, the unit of measurement can significantly impact your project's outcome. Whether you're a professional engineer, a DIY enthusiast, or a student learning the ropes, knowing your AWG, MM2, and amp will ensure you're working safely and effectively.

American Wire Gauge (AWG)

The American Wire Gauge, or AWG, is a standard used primarily in North America to measure the diameter of a solid, round, non-ferrous wire. It's often used in low-voltage applications and electrical cords.

the table shows how many different types of electrical equipment are available for each type of device
the table shows how many different types of electrical equipment are available for each type of device
AWG para mm²
AWG para mm²
MM2 to AWG - Wire Size Conversion Chart, Table, & Calculator [PDF]
MM2 to AWG - Wire Size Conversion Chart, Table, & Calculator [PDF]

AWG uses a logarithmic scale that starts at 0 (the thickest) and goes up to 40 (the thinnest). So, a larger AWG number indicates a smaller wire diameter. The AWG scale is designed to approximate a constant increase in resistance per unit length as the wire diameter decreases.

AWG vs Resistance

As you might expect, the AWG affects a wire's resistance. The smaller the AWG number, the lower the resistance. This is due to the larger diameter of the wire, which offers less resistivity per unit length.

awg vs mm2 vs amp
awg vs mm2 vs amp
Conversión Awg - mm2
Conversión Awg - mm2
AWG Size Chart Complete Guide
AWG Size Chart Complete Guide

For instance, a 14 AWG wire has about half the resistance of a 16 AWG wire, making it more suitable for longer runs or higher current applications. However, heavier gauge wires (lower AWG numbers) are often stiffer and harder to work with, while lighter gauges (higher AWG numbers) are more flexible but have higher resistance.

AWG and Current Carrying Capacity

The current carrying capacity of a wire is another critical factor influenced by the AWG. The larger the wire diameter, the more current it can safely carry without overheating. For general-purpose, stranded, tinned copper wire, the typical current-carrying capacities are:

Wire Gauge (AWG) Allowable Current (A)
12 20
14 15
16 13
18 8

Millimeter Squared (MM2)

Millimeter squared (MM2 or mm²) is a unit of area used to measure the cross-sectional area of a conductor. It's a metric system unit commonly used in Europe and Asia. The larger the cross-sectional area, the lower the resistance, and the greater the current-carrying capacity of the wire.

an image of two cartoon characters pulling each other's strings with the caption vots, amps, and ohms
an image of two cartoon characters pulling each other's strings with the caption vots, amps, and ohms
how to find the right wire size for 100 amp in awg
how to find the right wire size for 100 amp in awg
Conversión AWG - mm2 500 a 1000
Conversión AWG - mm2 500 a 1000
What AWG Wires To Use | IntoFPV Forum
What AWG Wires To Use | IntoFPV Forum
mm² to AWG: A Comprehensive Guide to Wire Size Conversion
mm² to AWG: A Comprehensive Guide to Wire Size Conversion
Parametros estandar AWG
Parametros estandar AWG

To calculate the cross-sectional area of a round conductor, you can use the formula: Area = (π * r²), where r is the radius of the conductor in millimeters. Since the AWG doesn't provide the radius directly, you can look up an AWG to MM2 conversion table to find the approximate cross-sectional area of a wire.

MM2 and Current Carrying Capacity

The current-carrying capacity of a wire also depends on its cross-sectional area measured in MM2. The general rule of thumb is that a wire can safely carry 1 ampere per square millimeter of cross-sectional area. However, this is a simplification, and the actual current-carrying capacity depends on the wire's insulation, operating temperature, and ambient conditions.

Here's an example of current-carrying capacity for some common MM2 values, assuming 70°C operating temperature and PVC insulation:

AWG silicone cable specification
AWG silicone cable specification
three different types of batteries with the words current, voltage and resistance written on them
three different types of batteries with the words current, voltage and resistance written on them
an image of the awg vs swg table with numbers and times on it
an image of the awg vs swg table with numbers and times on it
  • 1.5 mm²: 17.5 A
  • 2.5 mm²: 26.5 A
  • 4 mm²: 44 A
  • 6 mm²: 62 A

Ampere (A)

The ampere, often abbreviated as 'A', is the SI unit of electric current. It's a measure of the amount of charge passed by a current-carrying wire per unit time, typically one second. In simple terms, an ampere is a unit of current.

When designing electrical systems, it's crucial to understand the relationship between the current-carrying capacity of a wire (measured in amperes) and its cross-sectional area (measured in MM2). The current-carrying capacity determines the size of fuses, circuit breakers, and other protective devices required for a safe and reliable installation.

Calculating Current with Ohm's Law

Ampere is directly related to voltage and resistance through Ohm's Law: V = IR, where V is voltage, I is current in amperes, and R is resistance in ohms. To find the current, rearrange the formula to I = V/R.

For example, if you have a 12V DC supply and a 5Ω load, the current is (12V / 5Ω) = 2.4A. Knowing the required current helps you choose the appropriate wire size (AWG or MM2) to safely carry that current without overheating.

In electrical engineering, understanding AWG, MM2, and amp is not just an academic exercise. It's a practical skill that ensures you're using the right wire, sized appropriately, and operating within the safe current limits. The next time you're selecting a wire for your project, or calculating the current for a circuit, you'll know exactly which unit to use and why.

💬 Comments ↗ Share ★ Save
AD