When it comes to electrical work, understanding cable sizes and gauges is crucial. Two common metrics used to measure cable size are American Wire Gauge (AWG) and the Circular Millimeter (mm²). This article aims to demystify these two measures and provide a practical guide on converting between them.

Before we dive into the conversion, let's first understand what these measurements represent. American Wire Gauge (AWG) is a North American industry standard for measuring the diameter of round, solid, non-ferrous conductors. On the other hand, the Circular Millimeter (mm²) is an SI units-based measure, widely used in Europe and Asia, that represents the cross-sectional area of a conductor.

Understanding American Wire Gauge (AWG)

AWG is based on a logarithmic scale, with larger numbers indicating smaller diameters. The scale starts at 0 for the largest wire size, and increases up to 40 for the smallest. The formula to calculate the diameter (D) of a wire in inches from its AWG size (n) is:

How to Calculate Cable Size from kW
How to Calculate Cable Size from kW
Cable Size Selection
Cable Size Selection
the spreadsheet is shown for each employee's status and their employees numbers
the spreadsheet is shown for each employee's status and their employees numbers

D = 0.127 * (36 - 3 * n) / 1000

Here's a simple table to illustrate the relationship between AWG and wire diameter:

Electrical Wire & Cable Sizes with Current Rating ⚡ Cheat Sheet for Safe Wiring Guide
Electrical Wire & Cable Sizes with Current Rating ⚡ Cheat Sheet for Safe Wiring Guide
MM2 to AWG - Wire Size Conversion Chart, Table, & Calculator [PDF]
MM2 to AWG - Wire Size Conversion Chart, Table, & Calculator [PDF]
758K views • 7.6K likes | Reel by Maa Khodal Electrician
758K views • 7.6K likes | Reel by Maa Khodal Electrician
AWG vs. Diameter (in inches)
AWGDiameter (in inches)
120.141
160.087
200.064
240.048

Converting AWG to mm²

To convert AWG to mm², we first need to convert the diameter from inches to millimeters, and then calculate the cross-sectional area. The formula for converting AWG to mm² (A) is:

A = (0.127 * (36 - 3 * n) / 1000)² * π * 1000000

Using this formula, we can convert AWG 16 to approximately 1.31 mm², AWG 20 to about 0.84 mm², and so on.

Cable size &rating
Cable size &rating
How to Convert Cable Size from AWG to Inches | InstrumentationTools
How to Convert Cable Size from AWG to Inches | InstrumentationTools
table size chart for cable sizes
table size chart for cable sizes
AWG Size Chart Complete Guide
AWG Size Chart Complete Guide
the industrial cable size chart is shown
the industrial cable size chart is shown
electrical wire sizes and ampity table with instructions for different types of wires on it
electrical wire sizes and ampity table with instructions for different types of wires on it

Converting mm² to AWG

To convert mm² to AWG, we can use the following approximation formula, which is a simplified version of the inverse of the AWG to mm² conversion:

n ≈ 36 - (1000 * √(A / (π * 1000000))) / 0.127

For example, to convert 2.5 mm² to AWG, we get n ≈ 15.4. Rounding to the nearest whole number, we get AWG 15.

the table is shown with numbers and symbols for each element in this diagram, which are labeled
the table is shown with numbers and symbols for each element in this diagram, which are labeled
AWG Wire Gauge Chart: Complete Guide to Wire Sizes, Ampacity, and Resistance
AWG Wire Gauge Chart: Complete Guide to Wire Sizes, Ampacity, and Resistance

Understanding Circular Millimeter (mm²)

The Circular Millimeter (mm²) is directly proportional to the current-carrying capacity of the wire. The higher the mm² value, the larger the wire's cross-sectional area and its ability to conduct more electricity. Here's a simple comparison of mm² values to AWG sizes for reference:

  • 0.5 mm² ≈ AWG 16
  • 1.5 mm² ≈ AWG 12
  • 2.5 mm² ≈ AWG 10
  • 6 mm² ≈ AWG 4

Choosing the Right Wire Size

When selecting a wire size, it's essential to consider the current-carrying capacity, voltage drop, and ampacity ratings. Always choose a wire size that's appropriate for the electrical circuit's requirements and fall within the safe working range to prevent electrical hazards and equipment damage.

Wiring Tables

For quick reference, many electrical codes and standards provide wiring tables that list acceptable wire sizes for various current ratings, in both AWG and mm². These tables help ensure that you're using the correct wire size for a given application, improving electrical safety and reliability.

Understanding and converting between AWG and mm² is critical in today's globalized world, where electrical components may be sourced from different regions with varying measurement standards. Accurate conversions help ensure electrical safety, equipment protection, and efficient power distribution. As always, if you're unsure about any aspect of electrical work, consult a professional or relevant electrical codes and regulations.