DC Cable Size Calculation Formula: Simplified Guide

By

Choosing the right DC (Direct Current) cable size is critical for ensuring the safety, efficiency, and longevity of your electrical system. But how do you calculate the appropriate size? This guide will walk you through the formula and key considerations for DC cable size calculation, helping you make informed decisions.

Before diving into the formula, let's first understand the basics. DC cable size is determined by the current it's designed to carry and the purity of the copper conductor used. The larger the cable size, the more current it can carry, and the less voltage drop you'll experience. However, larger cables are more expensive and bulkier, so it's essential to strike a balance.

Understanding the DC Cable Size Calculation Formula

The primary formula for calculating DC cable size is based on the current flowing through the cable and the loss of voltage (drop) you're willing to accept. It's expressed as:

Cable Size Selection
Cable Size Selection
an electrical calculator with the text how to calculate cable size mm2 for 3 phase
an electrical calculator with the text how to calculate cable size mm2 for 3 phase
the table is shown with numbers and symbols for each element in this diagram, which are labeled
the table is shown with numbers and symbols for each element in this diagram, which are labeled

Cable Size (in mm²) = (Current (in Amperes) * Length (in meters)) / (Allowable Voltage Drop (in Volts))

The Basic Formula: Understanding the Variables

Let's break down each component of the formula:

How to Calculate Cable Size from kW
How to Calculate Cable Size from kW
What Size Wire For 12 Volt Dc
What Size Wire For 12 Volt Dc
Electrical Wire & Cable Sizes with Current Rating ⚡ Cheat Sheet for Safe Wiring Guide
Electrical Wire & Cable Sizes with Current Rating ⚡ Cheat Sheet for Safe Wiring Guide
  1. Cable Size (in mm²): This is the cross-sectional area of the copper conductor in the cable, usually measured in square millimeters (mm²).
  2. Current (in Amperes): This is the amount of electrical current that will flow through the cable under normal operating conditions.
  3. Length (in meters): This is the total length of the cable from one point to another.
  4. Allowable Voltage Drop (in Volts): This is the acceptable voltage loss along the cable. It depends on the specific requirements of your system.

Adjusting for Conductor Resistivity and Copper Purity

The basic formula assumes 100% IACS (International Annealed Copper Standard) for copper purity, which is not always the case. To account for this, the formula is often adjusted to:

Cable Size (in mm²) = (Current (in Amperes) * Length (in meters)) / ((Allowable Voltage Drop (in Volts) * (Copper Purity / 100)) / (Conductor Resistivity (in Ohm*mm²/m)))

Where:

758K views • 7.6K likes | Reel by Maa Khodal Electrician
758K views • 7.6K likes | Reel by Maa Khodal Electrician
1.3K reactions · 236 shares | IEC Standard Cable Size Calculation with example ⚡👇 #fblifestyle #electrical #education #Cable #reelsvideoシ | Md. Shamim Hassan | Facebook
1.3K reactions · 236 shares | IEC Standard Cable Size Calculation with example ⚡👇 #fblifestyle #electrical #education #Cable #reelsvideoシ | Md. Shamim Hassan | Facebook
the electrical cable size calculator
the electrical cable size calculator
216K views | Reel by 𝐄𝐥𝐞𝐜𝐭𝐞𝐝 𝐎𝐟𝐟𝐢𝐜𝐢𝐚𝐥
216K views | Reel by 𝐄𝐥𝐞𝐜𝐭𝐞𝐝 𝐎𝐟𝐟𝐢𝐜𝐢𝐚𝐥
Cable size &rating
Cable size &rating
the size and measurements for cable sizes
the size and measurements for cable sizes
  1. Copper Purity: This is the purity of the copper used in the cable, typically expressed as a percentage of the IACS standard.
  2. Conductor Resistivity: This is the resistance of the copper conductor at 20°C, usually given as 0.017241 Ohm*mm²/m for copper of standard purity.

Steps to Calculate DC Cable Size

Now that we understand the formula let's go through a practical example:

Suppose you need to select a DC cable for a 10-meter distance, with a current flow of 50 Amperes, and you're willing to accept a voltage drop of 1 Volt. The copper purity is 98% IACS, and the conductor resistivity is 0.017241 Ohm*mm²/m. Here's how you would calculate it:

Step 1: Adjust the Allowable Voltage Drop for Copper Purity

First, adjust the allowable voltage drop to account for the copper purity:

table size chart for cable sizes
table size chart for cable sizes
3-Phase Cable Size Calculation – Practical Engineering Approach (11 kV / LV Industrial Feeders) This example shows a complete, standards-based method to select power cables for a 365 kW 3-phase load… | Amir Sohail . PE Eng
3-Phase Cable Size Calculation – Practical Engineering Approach (11 kV / LV Industrial Feeders) This example shows a complete, standards-based method to select power cables for a 365 kW 3-phase load… | Amir Sohail . PE Eng

Adjusted Allowable Voltage Drop = (Allowable Voltage Drop * (Copper Purity / 100))

For our example, this would be (1 Volt * 0.98) = 0.98 Volts.

Step 2: Plug in the Values into the Formula

Now, plug the values into the adjusted formula:

Cable Size (in mm²) = (50 Amperes * 10 meters) / (0.98 Volts / 0.017241 Ohm*mm²/m)

Step 3: Calculate the Result

This calculation gives us a cable size of approximately 307.32 mm². Rounding up, you would choose a 350 mm² cable for your system.

And there you have it! With this formula and these steps, you're well on your way to selecting the right DC cable size for your needs. Always remember to consult the specific requirements of your system and local regulations to ensure your calculations are accurate and safe. Stay empowered!