Ground Conductor Sizing Guide for Parallel Feeders

By

The sizing of a ground conductor for parallel feeders is a critical aspect of electrical system design. It's not just about meeting code requirements, but also about ensuring the safety and reliability of your electrical system. The ground conductor size can influence the safety of your equipment and even save lives in case of faults.

Grounding is essential in electrical systems to facilitate the functioning of safety devices and to protect personnel and equipment from harmful electrical faults. The ground conductor, also known as the grounding electrode conductor, facilitates this by providing a low-impedance path to the earth.

Why Size Matters

The size of the ground conductor significantly affects its ability to conduct fault current safely back to the earth. A correctly sized ground conductor can prevent excessive voltage drops, heat generation, and potential damage to equipment during fault conditions.

How to Size Feeder Conductors with Overcurrent Protection
How to Size Feeder Conductors with Overcurrent Protection
How to Size Service-Entrance Conductors and Feeder Cables?
How to Size Service-Entrance Conductors and Feeder Cables?
How to Size Equipment Grounding Conductor (EGC)?
How to Size Equipment Grounding Conductor (EGC)?

Under-sizing your ground conductor can lead to hazardous conditions. In case of a fault, the insufficient current-carrying capacity can cause excessive voltage drops at the fault location. This can result in burning or melting of the conductor, leading to safety hazards.

calculate Ground Conductor Size

To size a ground conductor, you need to consider the fault current that could flow through the system. The National Electrical Code (NEC) provides guidelines for this. For piace, the NEC requires that the grounding electrode conductor be sized based on the calculated fault current.

How to Size Grounding Electrode Conductor (GEC)?
How to Size Grounding Electrode Conductor (GEC)?
Sizing of Conductors Related to Grounding & Bonding
Sizing of Conductors Related to Grounding & Bonding
an image of a water source diagram
an image of a water source diagram

Here's a simplified formula for calculating the size of the ground conductor: Conductor Size = ILA x KLA, where ILA is the longest available conductor length and KLA is the largest ungrounded conductor size. A safety factor is also added to account for uncertainty in calculations.

Conductor Types and Sizes

While the size of the ground conductor is critical, the type of conductor also plays a significant role. Copper and aluminum are commonly used, with copper being the preferred choice due to its superior corrosion resistance and higher conductivity.

The size of the ground conductor is typically expressed in American Wire Gauge (AWG). Common ground conductor sizes include 4 AWG, 2 AWG, and even larger sizes for high-current applications. The choice of size and type depends on the specific application and the calculated fault current.

the diagram shows how to use single line diagrams for outgrowing feeder transformer
the diagram shows how to use single line diagrams for outgrowing feeder transformer
Grounding Conductor Size Calculator — NEC 250
Grounding Conductor Size Calculator — NEC 250
Part 6 - Sizing Motor Feeder Conductors and Cables
Part 6 - Sizing Motor Feeder Conductors and Cables
the size and length of wires are shown in this graphic above which wire sizes do you need to use?
the size and length of wires are shown in this graphic above which wire sizes do you need to use?
Ground Wire Size Chart
Ground Wire Size Chart
Motor Calculations — Part 2: Feeders
Motor Calculations — Part 2: Feeders

Parallel Feeders and Grounding

In parallel feeder systems, multiple feeders are used to distribute electric power to different parts of a facility. Proper grounding is crucial in these systems to ensure the safety of personnel and equipment.

A common misconception is that parallel feeders need individual ground conductors. However, NEC allows for a shared ground conductor, provided it meets the size requirements based on the total fault current calculated for all feeders.

Shared Ground Conductors

Using a shared ground conductor can simplify the design and reduce costs. However, it's important to ensure that the shared ground conductor is continuous and does not rely on equipment grounding connections for its continuity.

Table 250.102(C)(1) Sizing Grounded Conductors, Bonding Conductors, and Bonding Jumpers
Table 250.102(C)(1) Sizing Grounded Conductors, Bonding Conductors, and Bonding Jumpers
the diagram shows how to install an electric fence
the diagram shows how to install an electric fence
Factors influencing requirements for a good grounding system
Factors influencing requirements for a good grounding system

The NEC provides rules for sharing ground conductors. For instance, the ground conductor for parallel feeders must be continuous and no equipment grounding connections can be relied upon to provide a ground path for the feeder conductors.

Parallel Feeders and Grounding Electrode Conductor Size

When sizing a ground conductor for parallel feeders, you need to consider the total fault current that could flow through the system. The NEC requires that the grounding electrode conductor be sized based on the fault current calculated for all feeders.

In case of a fault on one feeder, the ground conductor must be able to carry the fault current for all feeders without exceeding its current-carrying capacity. Therefore, the size of the ground conductor must be based on the total fault current, not just the fault current for a single feeder.

Understanding and correctly applying these principles is key to designing safe and reliable electrical systems. Always refer to the NEC and other applicable codes for specific requirements. If you're unsure, consult a licensed electrical engineer or technician.