Determining the correct ground wire size is a vital aspect of electrical installation, ensuring both safety and compliance with electrical codes. For a 125 amp (A) circuit, understanding the wire size requirements is crucial. Let's delve into the details of selecting the appropriate ground wire size for this common electrical load.

First, it's essential to understand that the ground wire size does not depend solely on the circuit's ampacity but also on the wiring method, type of grounding, and the specific electrical code you're following. In this article, we'll primarily focus on the 2020 National Electrical Code (NEC), which is widely adopted in the United States.

Understanding Grounding Types

The first step in determining the appropriate ground wire size is to identify the type of grounding used in your circuit. The NEC defines three types of grounding: solid grounding, high-impedance grounding, and isolated grounding. For most residential and commercial applications, solid grounding is employed, which requires a continuous grounded conductor.

the size and length of wires are shown in this graphic above which wire sizes do you need to use?
the size and length of wires are shown in this graphic above which wire sizes do you need to use?
Electrical Wire & Cable Sizes with Current Rating ⚡ Cheat Sheet for Safe Wiring Guide
Electrical Wire & Cable Sizes with Current Rating ⚡ Cheat Sheet for Safe Wiring Guide
an info poster showing different types of wires
an info poster showing different types of wires

High-impedance and isolated grounding methods are typically used for specific equipment and circuits, such as those in hospital operating rooms, and have different wire sizing requirements. This article will concentrate on the solid grounding method, which is most commonly used and follows a simple, size-based rule for ground wire conductors.

Ambient Temperature and Environment

Before choosing a ground wire size, consider the ambient temperature and environmental conditions where the wire will be installed. The NEC categorizes ambient temperatures into four classes, ranging from 0°C to 105°F, with class 5 being the most extreme due to the harshest environmental conditions.

the size and measurements for an amp speaker with different types of speakers in each section
the size and measurements for an amp speaker with different types of speakers in each section
the wires and cable size chart for different types of electrical wire sizes are shown in red, blue, yellow, and orange
the wires and cable size chart for different types of electrical wire sizes are shown in red, blue, yellow, and orange
Coduri voltaj capacitoare.jpg
Coduri voltaj capacitoare.jpg

The wire type and size you select should accommodate the designated temperature rating for the specific environment. For most residential and commercial applications, a non-metallic-sheathed (NM) cable rated for 90°C is sufficient. This type of cable is most commonly used in dry, indoor locations and has a 90°C rating, allowing for up to a 20% derating in wire size.

Conductor Sizes and Ampacities

The ground wire size selection depends on the circuit's ampacity and the allowed derating. The NEC provides a table of conductor sizes and their corresponding ampacities for various types of conductors, such as copper or aluminum, and different environmental conditions. For a 125A circuit, the ground wire size should not exceed the circuit's ampacity.

If you're using NM cable with a 90°C rating, you must derate the conductor size by 20% to account for the higher ambient temperature. This derating ensures the ground wire can safely carry current under the specified conditions. Here's an example: for a 125A circuit, the originally allowed copper conductor sizes are 8 AWG and 6 AWG. After derating by 20%, the allowable sizes are 10 AWG and 8 AWG.

Ground Wire Size Chart
Ground Wire Size Chart
the diagram shows how to wire an electrical device in order to control current voltages
the diagram shows how to wire an electrical device in order to control current voltages
the industrial cable size chart is shown
the industrial cable size chart is shown
Romex Cable
Romex Cable
Breaker and Wire Size for Electric Dryers: Complete Guide
Breaker and Wire Size for Electric Dryers: Complete Guide
What Size Wire to Run to Shed?
What Size Wire to Run to Shed?

Ground Wire Sizing Examples

To ensure accuracy, let's examine a few examples based on the 2020 NEC for a 125A, solidly grounded circuit using NM cable with a 90°C rating:

Example 1: 14 AWG Non-Metallic Sheathed Cable (Type NM)

For a 14 AWG NM cable with a 90°C rating, the ampacity is 15A. Since this is less than the 125A circuit requirement, it cannot be used as a feeder, but it may be used as a branch circuit if the load does not exceed 15A. In this case, the ground wire size would be 14 AWG.

Example 2: 12 AWG Non-Metallic Sheathed Cable (Type NM)

For a 12 AWG NM cable with a 90°C rating, the ampacity is 20A. After derating by 20%, the allowed ampacity is 16A. While this meets the requirement for a 125A circuit, it is advisable to use a larger size for better integrity and safety. In this scenario, the ground wire size would be 12 AWG.

Circuit Breaker & Wire Size Compatibility Guide: Amperage & Gauge Chart.
Circuit Breaker & Wire Size Compatibility Guide: Amperage & Gauge Chart.
an image of the ground with pipes and wires attached to it's side wall
an image of the ground with pipes and wires attached to it's side wall
Why you need ground wire
Why you need ground wire

Always double-check your chosen ground wire size with the most up-to-date electrical code and consult a local electrical inspector if you have any doubts about your specific installation. Ensuring the correct ground wire size helps maintain the safety and reliability of your electrical system.