Determining Electric Tankless Water Heater Current: Amps Needed
Electric tankless water heaters have gained popularity due to their energy efficiency and space-saving design. A common question homeowners and electricians ask is, "How many amps does an electric tankless water heater take?" This article will delve into the power consumption of these appliances to help you make informed decisions when considering or installing an electric tankless water heater.
The power consumption of an electric tankless water heater is measured in amps and varies based on the model, size, and flow rate. Generally, these units fall into two categories: 110V and 220V models. Let's explore each type and their respective amp draw.
110V Electric Tankless Water Heaters
These models operate on a standard household 110V electrical circuit. They are ideal for low-flow applications, such as washing hands or showering.
Lower-end Models (Less than 5 GPM)
Typically, lower-end 110V tankless water heaters with a flow rate of less than 5 gallons per minute (GPM) draw between 10 to 15 amps. For instance, popular models like the Stiebel Eltron DAC Mini and EcoSmart ECO 11 draw around 13 amps at their maximum output.
To power these units, you'll need a dedicated 15-amp circuit. Here's a simple calculation: 110V x 13A = 1430W (wattage) or 1.43kW (kilowatt).
Higher-end Models (More than 5 GPM)
Higher-end 110V models with a flow rate of more than 5 GPM may draw between 15 to 20 amps. An example is the Bosch Tronic GWH-11, which draws up to 17.5 amps. For these heaters, you'll need a dedicated 20-amp circuit.
At maximum output, these models consume around 2030W (2.03kW). Be cautious, as they might trip standard 15-amp circuits.
220V Electric Tankless Water Heaters
These models operate on a 220V electrical circuit and are designed for medium to high-flow applications and larger households. They typically draw less current but have higher power output.
20-amp Circuits (10-15 GPM)
Many 220V models with flow rates between 10 to 15 GPM connect to a 20-amp circuit. For example, the Takagi T-KJr2-IN-NP draws 81.6 amps at its peak performance. Here's the math: 220V x 81.6A = 17948W (17.948kW).
While these models require a higher amp circuit, they are more energy-efficient and can provide a more consistent hot water supply.
30-amp Circuits (16-20+ GPM)
Larger 220V models with flow rates of 16 GPM and above need a 30-amp circuit. The Rheem RTG-95-XLN, for instance, draws 122 amps at maximum output. The calculation here is: 220V x 122A = 26840W (26.84kW).
These heaters can supply an abundant hot water supply for large homes, but they require careful electrical planning and professional installation.
When choosing an electric tankless water heater, consider your household's hot water needs, electrical capacity, and local building codes. Consult with a licensed electrician to ensure safe and proper installation. Lastly, always review the manufacturer's instructions for specific power requirements, as models and brands may vary.