How to Calculate Cable Size in sq mm

By

Calculating cable size in square millimeters (sq mm) is a crucial step in electrical design and installation. The cross-sectional area of a cable is a key factor in determining its current-carrying capacity and safe operating conditions. Here, we'll guide you through the process, providing clear, step-by-step instructions and practical examples.

Whether you're an electrical engineer, a seasoned electrician, or a DIY enthusiast, understanding how to calculate cable size in sq mm is an essential skill. Let's dive in and simplify this process.

Understanding Cable Standards and Sizes

before calculating cable size, it's important to familiarize yourself with international cable standards. These guidelines ensure consistency and safety in electrical design and installation worldwide. The most commonly used standards are the British Standard (BS 7870), the International Electrotechnical Commission (IEC) standards, and the American Wire Gauge (AWG) system.

How to Calculate Cable Size from kW
How to Calculate Cable Size from kW
an electrical calculator with the text how to calculate cable size mm2 for 3 phase
an electrical calculator with the text how to calculate cable size mm2 for 3 phase
Cable Size Selection
Cable Size Selection

In this guide, we'll focus on the British Standard and IEC systems, as they use the square millimeter (sq mm) unit for cable size. The AWG system, commonly used in the U.S., designates wire sizes based on gauge numbers.

Cable Cross-sectional Areas and Current Carrying Capacity

The current carrying capacity (CCC) of a cable refers to the maximum amount of current it can safely conduct without overheating. The CCC is directly proportional to the cable's cross-sectional area (CSA), measured in square millimeters. A larger CSA means a higher CCC and vice versa.

How to Calculate Cable Size in Sq Mm: A Comprehensive Guide
How to Calculate Cable Size in Sq Mm: A Comprehensive Guide
the electrical cable size calculator
the electrical cable size calculator
Cable size &rating
Cable size &rating

For example, a 1.5 sq mm cable has a lower CCC than a 6 sq mm cable. The exact CCC for a given cable size depends on the type of conductor (copper, aluminum, etc.), the type of insulation, and the wire's temperature rating.

Cable Construction and Stranding

Most electrical cables consists of one or more metallic conductors, surrounded by insulation, and often twisted together in a process called stranding. The particular stranding method affects the cable's overall CSA and CCC. Common stranding methods include solid (single) conductors, stranded conductors, and twisted pairs.

Sherman-cabled and (\%)-cabled conductors, often used in power cables, have more complex strand layouts. When calculating cable size in sq mm, you must consider the cable's specific construction and stranding method to determine its CSA accurately.

the table is shown with numbers and symbols for each element in this diagram, which are labeled
the table is shown with numbers and symbols for each element in this diagram, which are labeled
758K views • 7.6K likes | Reel by Maa Khodal Electrician
758K views • 7.6K likes | Reel by Maa Khodal Electrician
How to select cable size How to calculate cable size for Motor
How to select cable size How to calculate cable size for Motor
three wires are shown with the words how to calculate cable size and breaker
three wires are shown with the words how to calculate cable size and breaker
table showing the current voltages for different types of wires
table showing the current voltages for different types of wires
table size chart for cable sizes
table size chart for cable sizes

Calculating Cable Size in Sq mm

Now that we've established the fundamentals, let's delve into the practical steps for calculating cable size in sq mm. We'll use the British Standard (BS 7870) and IEC standards as references.

These standards provide tables of cable sizes and their corresponding cross-sectional areas. To calculate cable size in sq mm, you'll need to know the desired current carrying capacity and select an appropriate cable size from the standard's table.

Step-by-Step Guide to Cable Size Calculation

Follow these steps to calculate cable size in sq mm:

Cable Gland Chart: A Guide for Electrical Design | Gurunath Tatphale posted on the topic | LinkedIn
Cable Gland Chart: A Guide for Electrical Design | Gurunath Tatphale posted on the topic | LinkedIn
table size and load amp breaker size chart with measurements for each type of cable
table size and load amp breaker size chart with measurements for each type of cable
  1. Determine the maximum current the cable needs to carry (I) in amperes (A). This depends on the load's power requirements and the desired voltage drop.
  2. Consult the relevant cable standard (e.g., BS 7870 or IEC) for a table of cable sizes and their corresponding CSAs in sq mm.
  3. Identify the cable size with a CSA that can safely accommodate the desired current (I). Use the following relationship between CSA (in sq mm), current (I in A), and the material's resistivity (ρ in Ω·mm²/m) to guide your selection:

CSA = I * (ρ / (J * ΔT))

where:

  • J is the acceptable current density (in A/mm²) as per the standard (e.g., 6 A/mm² for PVC insulated cables at 70°C under normal conditions).
  • ΔT is the temperature rise above the ambient temperature (in °C).

For instance, using a 70°C temperature rise and a 6 A/mm² current density, the minimum CSA for a given current I can be approximated as:

CSA = I * 115.7

Or, if you prefer to work in milliamperes (mA), you can use the following approximation:

CSA (in mm²) ≈ I (in mA) / 9

This approximation helps you estimate the required CSA efficiently. However, it's crucial to consult the appropriate cable standard for precise values and safety margins.

Finally, select a cable with a CSA slightly larger than the calculated value to ensure a suitable safety margin for future load expansions and potential voltage drops.

Cable Sizing Examples

Let's apply our knowledge to some practical examples:

Example 1: A 32 A Circuit

For a 32 A circuit with a 70°C temperature rise and a 6 A/mm² current density, the minimum CSA required can be calculated as follows:

CSA = 32 A * 115.7 ≈ 3683 mm²

Consulting the cable standard, we find that a 16 sq mm² cable has a CSA of approximately 400 sq mm, which provides an adequate safety margin for this application.

Example 2: A 100 mA Circuit

For a low-current circuit with only 100 mA, using our approximation, the minimum CSA required can be estimated as:

CSA ≈ 100 mA / 9 ≈ 11.11 mm²

Cables with CSAs of 1.5 sq mm or greater are suitable for this application, providing ample safety margins.

In summary, calculating cable size in sq mm requires careful consideration of the intended load's current requirements, the cable's construction and stranding method, and the appropriate cable standard. Always select a cable with a CSA that safely accommodates the desired current and allows for future expansion.

As a responsible electrical engineer, electrician, or DIY enthusiast, understanding how to calculate cable size in sq mm is an invaluable skill. By following this comprehensive guide and the relevant cable standards, you'll ensure safe, efficient, and reliable electrical installations.

Now that you've mastered the art of cable size calculation, you're well-equipped to tackle your next electrical project with confidence. Happy calculating!