If you're planning to replace or install a shower, determining the correct cable size for your shower heater is crucial. Electrical safety is paramount in bathroom installations due to the high moisture levels. Here's a comprehensive guide on how to check shower cable size.

Before we delve into the specifics, it's essential to understand that the cable size is determined by the current rating of your shower - usually measured in amps (A). The higher the amperage, the larger the cable needed. A typical shower uses between 7.5 to 10 amps, but it's always best to double-check the specifications of your specific shower unit.

Understanding Shower Cable Gauges

The cable gauge refers to the thickness of the electrical wire. The smaller the gauge number, the thicker the wire. For instance, a 16 AWG (American Wire Gauge) cable is thicker than a 18 AWG cable. Thicker cables can handle more current without overheating, making them safer for higher amperage applications like showers.

How to Fit an Electric Shower | Victorian Plumbing
How to Fit an Electric Shower | Victorian Plumbing
the shower head and handset are labeled in this diagram
the shower head and handset are labeled in this diagram
an image of a shower head and handset with instructions for the functions in it
an image of a shower head and handset with instructions for the functions in it

Always ensure you use a cable gauge that can safely accommodate your shower's current rating. Undersized cables can overheat, potentially causing a fire or damaging your shower.

Cable Gauge for Common Shower Current Ratings

Here's a general guide for choosing the right cable gauge based on your shower's current rating:

an electrical wiring diagram for a shower
an electrical wiring diagram for a shower
the diagram shows how to install shower head and hand shower with wall mount body sprayers
the diagram shows how to install shower head and hand shower with wall mount body sprayers
How an Electric Shower Works and Common Electric Shower Faults
How an Electric Shower Works and Common Electric Shower Faults
  • Up to 7.5A (e.g., electric showers without a pump): 18 AWG cable
  • 8-10A (e.g., electric showers with a pump): 16 AWG cable
  • 11-13A (e.g., power showers): 14 AWG cable

Always refer to the manufacturer's guidelines for precise information. If you're unsure, it's safer to opt for a larger cable gauge to handle the maximum current your shower might draw.

Checking Your Existing Cable Size

If you're replacing an existing shower, you can check the cable size of the old unit:

  1. Isolate the electrical circuit by switching off the fuse, then confirm it's off using a voltage tester.
  2. Remove the shower unit's electrical connector. Look for numbers or letters next to the cable insulation - these usually indicate the cable gauge. Common markings include:
    • 16 AWG: SJOOW-16, 16/2, 16 AWG NM-B
    • 18 AWG: SJOOW-18, 18/2, 18 AWG NM-B
  3. If no markings are visible, use a ruler or callipers to measure the cable insulation's outer diameter. Compare this with the chart below to identify the cable gauge:
Cable Gauge Approximate Outer Diameter (mm)
16 AWG 5.0 - 5.2
18 AWG 4.2 - 4.4

If your existing cable is too small for your new shower, replace it with an appropriately sized one.

Medidas banheiro
Medidas banheiro
ELECTRIC INSTANT WATER HEATER TYPICAL DETAIL - Mepengineerings
ELECTRIC INSTANT WATER HEATER TYPICAL DETAIL - Mepengineerings
the measurements for a shower head and hand shower
the measurements for a shower head and hand shower
a bathroom with measurements for the shower head
a bathroom with measurements for the shower head
the height chart for a shower head and hand held shower controls, with instructions to measure it
the height chart for a shower head and hand held shower controls, with instructions to measure it
two diagrams showing the different parts of an electrical device, and how they are connected to each
two diagrams showing the different parts of an electrical device, and how they are connected to each

Installing the Correct Cable Size

Once you've determined the correct cable size for your shower, ensure you follow safe installation practices:

Use an appropriately sized cable, and always run it through the nearest hide-a-way box or trench, keeping it out of reach. Regularly check the cable for any signs of damage or wear. If you're unsure about any aspect of your shower's electrical installation, consult a licensed electrician.

Using Cable Connectors and Junction Boxes

For extensions or connections, use high-quality, correctly rated cable connectors and junction boxes. These help maintain electrical safety and prevent overheating. Always follow the manufacturer's guidelines for proper usage.

the diagram shows how to install an overhead shower head and hand shower arm, which is located
the diagram shows how to install an overhead shower head and hand shower arm, which is located
a man standing in front of a shower with the caption, you should not be able
a man standing in front of a shower with the caption, you should not be able

Regularly inspecting and maintaining your shower cable ensures your bathroom remains a safe, comfortable space. With the correct cable size, you won't just have a great shower experience, but you'll also enjoy the peace of mind that comes with safety and durability.

💬 Comments ↗ Share ★ Save
AD