Circuit Breaker Capacity: Make & Break Formula Unveiled

By

Circuit breakers are essential components in electrical systems, safeguarding against short circuits and overloads. Their capacity to break and make circuits is defined by their interrupting capacity, which can be calculated using a formula. This article delves into understanding and calculating the making and breaking capacity of circuit breakers.

Before diving into the formula, let's clarify some key aspects. The making capacity refers to the maximum current a circuit breaker can withstand when it closes on a live circuit, while the breaking capacity is the maximum current it can interrupt when opening under normal conditions.

Understanding Current Ratings

The making and breaking capacity of a circuit breaker is closely tied to its current ratings. These ratings help determine the intensity of the current a breaker can safely handle without tripping.

Circuit Breaker Making Capacity
Circuit Breaker Making Capacity
How To Calculate The Value Of The Breaking Capacity - Sciencing
How To Calculate The Value Of The Breaking Capacity - Sciencing
349K views · 2.9K reactions | 20A Circuit Breaker Sample Computation #electricaltutorial | KoyZzz
349K views · 2.9K reactions | 20A Circuit Breaker Sample Computation #electricaltutorial | KoyZzz

There are three main current ratings to consider:

  • Nominational Current (In): The rated current at which the circuit breaker is designed to operate continuously.
  • Making Current (Im): The maximum current the circuit breaker can handle when it's closed on a live circuit.
  • Breaking Current ( Ib): The maximum current the circuit breaker can safely interrupt when opened.

Making Capacity Formula

The making capacity (Im) of a circuit breaker is typically expressed as a multiple of its nominal current (In). For AC systems, the formula to calculate the making capacity is:

Breaker Size Calculation (Basics)
Breaker Size Calculation (Basics)
the circuit breaker size chart for various types of power lines and other electrical equipment, including wires
the circuit breaker size chart for various types of power lines and other electrical equipment, including wires
an app showing different types of circuit breakers
an app showing different types of circuit breakers
Im = In * kF

Where kF is a factor depending on the voltage level and the type of current (AC or DC). For AC systems, kF is generally 2.5 for low voltage and 1.5 for high voltage.

For DC systems, the formula is slightly different:

Im = In * kF * (1 + 0.05 * t)

Here, t represents the time in seconds the circuit breaker remains closed after being energized.

an image of a diagram of the construction of a model case circuit breaker mccb
an image of a diagram of the construction of a model case circuit breaker mccb
#electricalengineering #breakersizing #engineeringmargins #acb #powersystems #industrialelectrical #electricaldesign #protectioncoordination #switchgear #powerdistribution #lvsystems #substation… | B Rajashekar
#electricalengineering #breakersizing #engineeringmargins #acb #powersystems #industrialelectrical #electricaldesign #protectioncoordination #switchgear #powerdistribution #lvsystems #substation… | B Rajashekar
Vacuum Circuit Breaker (VCB) Fault Analysis and Corrective Maintenance Procedure
Vacuum Circuit Breaker (VCB) Fault Analysis and Corrective Maintenance Procedure
How Circuit Breaker Works and Arc Initiation Methods
How Circuit Breaker Works and Arc Initiation Methods
the diagram shows different types of breakers and how they are used to operate them
the diagram shows different types of breakers and how they are used to operate them
𝐃𝐏 𝐄𝐥𝐞𝐜𝐜𝐭𝐫𝐨𝐧𝐢𝐜
𝐃𝐏 𝐄𝐥𝐞𝐜𝐜𝐭𝐫𝐨𝐧𝐢𝐜

Breaking Capacity Formula

The breaking capacity (Ib) of a circuit breaker is also expressed as a multiple of its nominal current. The formula for AC systems is:

Ib = In * kB

Where kB is a factor based on the voltage level and current type. For AC, kB is usually 10 for low voltage and 6 for high voltage. For DC, the formula is similar:

Ib = In * kB * (1 + 0.1 * t)

Again, t is the time in seconds the circuit breaker remains closed after being energized.

Md. Shamim Hassan
Md. Shamim Hassan
How to Calculate the size of Circuit breaker and fuse?
How to Calculate the size of Circuit breaker and fuse?
Fuse and Circuit Breaker Diagram | Physics Electricity Safety Notes
Fuse and Circuit Breaker Diagram | Physics Electricity Safety Notes

Understanding the Importance of these Calculations

Accurately determining the breaking and making capacity of circuit breakers is crucial for the safe and reliable operation of electrical systems. It ensures that the breakers can handle the current they may encounter, preventing premature tripping or failure.

Overrating or underrating the capacity of a circuit breaker can lead to various issues. Overrating can result in unnecessary expenses and reduced system efficiency, while underrating can lead to frequent tripping, safety hazards, or even catastrophic failures.

Real-world Examples and Best Practices

Consider a scenario where you're designing an electrical system for a commercial building. You'll need to size the circuit breakers based on the calculated making and breaking capacities. For instance, if the system's nominal current is 100A, and the making factor (kF) is 2.5, the making capacity (Im) would be:

Im = 100A * 2.5 = 250A

This means you'd need a circuit breaker rated for a making capacity of at least 250A.

In real-world scenarios, always choose circuit breakers that meet or exceed the calculated making and breaking capacities. Moreover, consider the system's specific conditions, such as the voltage level, type of current, and potential inrush currents.

As a final thought, understanding and correctly applying the making and breaking capacity formulas are key to ensuring the safety and reliability of your electrical systems. Regularly reviewing and recalculating these values as your systems change can help prevent unexpected issues and ensure your breakers perform their critical role effectively.