MC Cable NEC Code Requirements

By

The National Electrical Code (NEC), specifically article 725, dictates the installation requirements for metal clad (MC) cable. Compliance with these guidelines ensures safety and reliability for installations across residential, commercial, and industrial settings. Let's delve into the code requirements and their implications.

Understanding the NEC's scope and purpose is crucial before exploring MC cable specific provisions. The NEC establishes the requirements for installing electrical conductors and equipment. It aims to safeguard people and property from electrical hazards, enforceable by local authorities having jurisdiction.

MC Cable Installation Parameters

The NEC outlines installation requirements and restrictions for MC cable. Chapter 3, specifically article 725, defines MC cable, its rating, and allowable uses. MC cable is shear-gripping, insulated conductors encased within an overall nonmetallic sheath or covering.

NEC 2023 Code Changes Update
NEC 2023 Code Changes Update
Untangling Flexible Cord Requirements
Untangling Flexible Cord Requirements
Cable Tray Ampacity Derating: NEC 392.80 Explained
Cable Tray Ampacity Derating: NEC 392.80 Explained

MC cable size ratings range from 2 AWG to 1100 kcmil. The code details the neutral requirements, mandatory for mostinstallations. It requiresMarcellaneous conductors to be one of the following: the same size as the ungrounded conductors, 4 AWG for sizes 1/0 to 200 kcmil, or 2 AWG for sizes larger than 200 kcmil.

Conductor Sizing and Ampacity

The NEC specifies conductor sizes and ampacities for MC cables based on the type of service and the load demand. It employs the 75° C conductor ampacity or 90° C ampacity for larger sizes. The 75° C ampacity applies to wiring methods in dry locations and enclosed raceways, except for underfloor applications.

Mixture of Cables – 392.22(A)(1)(a): Understanding NEC Guidelines
Mixture of Cables – 392.22(A)(1)(a): Understanding NEC Guidelines
electrical construction nec codes
electrical construction nec codes
the new cable color code is shown
the new cable color code is shown

AMP hereby providing examples, where a 350 kcmil THHN/THWN-2, SCCR sized 350 kcmil has an ampacity of 214 A at 75° C. Conversely, a 500 kcmil MC cable possesses an ampacity of 265 A at 75° C.

Multiple Conductors and Fill within Raceways

The NEC places limits on the number of MC cable conductors and their size allowed within a raceway or enclosure. The Code specifies that the area occupied by the conductors shall not exceed 40% of the area of the raceway or enclosure. This rule applies regardless of the size or current rating of the conductors.

For instance, in a 2" EMT, the total area limits conductors of 800 kcmil or smaller. Larger conductors, like 1200 kcmil, may be used if the 40% cross-sectional area criterion is met.

NEC Article 310 Explained: Ampacity Rules, Wire Sizing & Code Secrets Electricians Must Know
NEC Article 310 Explained: Ampacity Rules, Wire Sizing & Code Secrets Electricians Must Know
How to Calculate Cable Tray Fill NEC 392 | Step by Step
How to Calculate Cable Tray Fill NEC 392 | Step by Step
wiring diagrams for different types of wires
wiring diagrams for different types of wires
the cable size chart for an electrical device, with different colors and sizes to choose from
the cable size chart for an electrical device, with different colors and sizes to choose from
Electrical Wire & Cable Sizes with Current Rating ⚡ Cheat Sheet for Safe Wiring Guide
Electrical Wire & Cable Sizes with Current Rating ⚡ Cheat Sheet for Safe Wiring Guide
the product information sheet for mega kabel products is shown in red, yellow and green
the product information sheet for mega kabel products is shown in red, yellow and green

Grounding and Bonding Requirements

The NEC mandates proper grounding and bonding of MC cable to ensure safe and reliable operations. The grounding conductor must be at least as large as the smallest ungrounded conductor in the cable but not smaller than the following:

  • 4 AWG for sizes up to 6 AWG
  • 3 AWG for sizes up to 1/0
  • 2 AWG for sizes up to 200 kcmil
  • 1 AWG for sizes up to 400 kcmil
  • 7/0 AWG for sizes up to 1100 kcmil

Grounding in Damp Locations

MC cables installed in damp or wet locations, such as outdoors, underground, or in water-interior spaces, must have an additional layer of protection through three methods: grounding conductor, overall jacket, or a separate conductor with no connection to any ungrounded conductor.

For, example, Article 300.5 armor or cable sheath, securely fastened, and used as a grounding electrode protects MC cables installed in bored, driven, or direct-bury applications.

the different types of electrical wires are shown in this diagram, and there is also an explanation
the different types of electrical wires are shown in this diagram, and there is also an explanation
the table is labeled with different types of cable and wire measurements for each type of device
the table is labeled with different types of cable and wire measurements for each type of device

Bonding to Other Enclosures

The NEC mandates bonding between MC cables and metal enclosures in which they are installed. This provision ensures safety by preventing the accumulation of voltage on metal enclosures, posing a shock hazard to personnel.

The bonding conductor must be a minimum of 16 AWG copper or 17 AWG aluminum, with a marked insulation that withstands the heat associated with the installation, not less than 90° C.

In drafting this piece, it's evident the NEC's MC cable guidelines prioritize safety and system reliability. Understanding these requirements empowers installers to apply best practices, ensuring compliance with regulations. Always verify local codes to ensure your project meets these crucial standards.