When it comes to choosing the right wire for your electrical needs, the two standards you'll often encounter are American Wire Gauge (AWG) and British Standard Wire (BSW), also known as Millimetre Square (mm²). Both are measurement systems for the circular cross-section of electrical conductors, but they have distinct units and ratings. This article aims to help you understand the difference between mm² and AWG, and how to convert between the two.

Before diving into the comparison, it's important to understand that neither system is universally superior. They are both widely accepted in their respective regions and serve their purpose effectively. The choice between the two usually depends on where you're based and which system is more commonly used in your region.

Understanding AWG

AWG, or American Wire Gauge, is an imperial unit used primarily in the United States and Canada to measure the diameter of electrical wire. The AWG scale is inverse, meaning as the gauge number increases, the wire diameter decreases. This can make it a bit confusing, so it's crucial to understand the standard AWG charts for accurate measurement.

mm² to AWG: A Comprehensive Guide to Wire Size Conversion
mm² to AWG: A Comprehensive Guide to Wire Size Conversion
MM2 to AWG - Wire Size Conversion Chart, Table, & Calculator [PDF]
MM2 to AWG - Wire Size Conversion Chart, Table, & Calculator [PDF]
AWG para mm²
AWG para mm²

Here's a quick reference to help you grasp the AWG measurements:

  • AWG 10: Wire diameter is approximately 2.587 mm
  • AWG 14: Wire diameter is approximately 1.628 mm
  • AWG 18: Wire diameter is approximately 1.016 mm
  • AWG 22: Wire diameter is approximately 0.643 mm

AWG chart for quick conversion

Here's a simple table for quick conversion from AWG to mm²:

the table shows how many different types of electrical equipment are available for each type of device
the table shows how many different types of electrical equipment are available for each type of device
AWG/SWG to mm/mm2, inch/inch2 & kcmil Calculator & Conversion
AWG/SWG to mm/mm2, inch/inch2 & kcmil Calculator & Conversion
Conversión AWG - mm2 500 a 1000
Conversión AWG - mm2 500 a 1000
Wire Gauge (AWG) Equivalent mm²
12 3.3
14 2.1
16 1.3
18 0.82

AWG to mm² conversion formula

For more precise conversion, you can use the following formula:

mm² = (0.127 * (36 - 2 * AWG))^2 / 4

This formula is derived from the inverse relationship between AWG and wire diameter.

What AWG Wires To Use | IntoFPV Forum
What AWG Wires To Use | IntoFPV Forum
AWG Wire Gauge Chart & Table – American Wire Gauge (AWG) Standards
AWG Wire Gauge Chart & Table – American Wire Gauge (AWG) Standards
Перевод площади сечения из awg в мм2 – СамЭлектрик.ру
Перевод площади сечения из awg в мм2 – СамЭлектрик.ру
Conversión Awg - mm2
Conversión Awg - mm2
Câble pour environnement difficile Rs Pro 0,34 mm², 22 awg, +105°C max, pvc Orange, 250m ( Prix pour Bobine de 250 Mètres )
Câble pour environnement difficile Rs Pro 0,34 mm², 22 awg, +105°C max, pvc Orange, 250m ( Prix pour Bobine de 250 Mètres )
an electrical calculator with the text how to calculate cable size mm2 for 3 phase
an electrical calculator with the text how to calculate cable size mm2 for 3 phase

Understanding mm²

Millimetre square, or mm², is part of the SI unit system, used primarily in Europe, Australasia, and many other parts of the world. It measures the cross-sectional area of a wire in square millimetres. Unlike AWG, mm² is a direct measurement and is, therefore, easier to understand.

Here are some common mm² measurements:

  • 2.5 mm²: Commonly used in 2.5 mm² cable with 1.5 mm² core
  • 4 mm²: Commonly used in 4 mm² cable with 2.5 mm² core
  • 6 mm²: Commonly used in 6 mm² cable with 3 mm² core

mm² to AWG conversion table

Here's a simple table for quick conversion from mm² to AWG:

Copper Wire Size Chart awg/swg: All You need to Know in mm or Inches
Copper Wire Size Chart awg/swg: All You need to Know in mm or Inches
Common AWG Wire Sizes - Inspection Gallery
Common AWG Wire Sizes - Inspection Gallery
AWG conversion table
AWG conversion table
Equivalent mm² Wire Gauge (AWG)
2.5 14 - 16
4 12 - 13

mm² to AWG conversion formula

To convert mm² to AWG, use the following formula:

AWG = 36 - 60 * (log10(0.127 * sqrt(4 * mm²)))

This formula is the inverse of the AWG to mm² conversion formula listed earlier.

Knowing how to convert between AWG and mm² is crucial for ensuring you have the right wire for your electrical needs. Always choose the right wire gauge or mm² rating for your specific application to ensure safety and optimal performance. Whether you're working with AWG or mm², always follow local electrical codes and consult a professional if you're unsure about any aspect of your project.