▲Wirig Diagram Hot
▲ ▲ ▼

THNN Wire Ampacity Table: PEC Calculations Explained

By

When it comes to electrical wiring, understanding the ampacity of wires is crucial to ensure safety and compliance with regulations. One such wire type that often brings up questions is THHN, or Thermoplastic High Heat-Resistant Nylon-coated wire. This guide delves into THHN wire ampacity, providing a table and key insights to help you make informed decisions.

THHN wire is widely used in industrial settings because of its high-temperature rating and excellent chemical resistance. Its ampacity, or current-carrying capacity, is a vital factor to consider when choosing the right wire size for a given application.

Understanding THHN Wire Ampacity

THHN wire ampacity depends on several factors, including conductor size, ambient temperature, number of conductors in a bundle, and insulation. The ampacity of THHN wire is typically derated based on these factors to ensure safe operation and prevent overheating.

an image of wire gauge and wire size ampacity chart for electrician's
an image of wire gauge and wire size ampacity chart for electrician's
Encore Wire Corporation
Encore Wire Corporation
an electrical wiring diagram showing the different types of wires and how they are connected to each other
an electrical wiring diagram showing the different types of wires and how they are connected to each other

Before we dive into the THHN wire ampacity table, let's briefly discuss the derating factors that can affect your wire's current-carrying capacity.

Ambient Temperature

Ambient temperature plays a significant role in THHN wire ampacity. Higher ambient temperatures lower a wire's ampacity because the conductor must dissipate more heat to maintain its operating temperature. THHN wires are derated according to the National Electrical Code (NEC) based on their installation environment.

an old table with numbers and times for different types of people in the united states
an old table with numbers and times for different types of people in the united states
Awg Wire Gauge Chart, Wire Gauge And Amperage Chart, Awg Wire Size Chart, Wire Gauge Amp Chart, Amperage Wire Gauge Chart, Wire Gauge Resistance Chart, Wire Gauge Chart And Ampacity, Dc Wire Gauge Chart, Wire Gauge Comparison Table
Awg Wire Gauge Chart, Wire Gauge And Amperage Chart, Awg Wire Size Chart, Wire Gauge Amp Chart, Amperage Wire Gauge Chart, Wire Gauge Resistance Chart, Wire Gauge Chart And Ampacity, Dc Wire Gauge Chart, Wire Gauge Comparison Table
where ampere
where ampere

For example, THHN wire installed in a duct or raceway with ambient temperatures exceeding 50°C (122°F) must be derated. The derating factors for different temperature ranges can be found in the NEC table 310.15(B)(16).

Conductor Size and Insulation

THHN wire ampacity also varies depending on its conductor size and insulation. Larger conductor sizes generally have higher ampacities. Additionally, different insulation types may affect a wire's ability to dissipate heat, thus influencing its ampacity.

Table 1 below provides a general guide for THHN wire ampacities based on conductor sizes. Keep in mind that these values are derated for 75°C ambient temperature, and additional derating may be required based on the-specific application and ambient temperature.

What is the Right Wire Size for 100-Amp Service Panel?
What is the Right Wire Size for 100-Amp Service Panel?
a paper with instructions to wire ampacty chart on it
a paper with instructions to wire ampacty chart on it
the table is labeled with different types of cable and wire measurements for each type of device
the table is labeled with different types of cable and wire measurements for each type of device
an assortment of different types of electrical wires
an assortment of different types of electrical wires
Wk Electric
Wk Electric
Stranded Wire Chart (AWG)
Stranded Wire Chart (AWG)

THHN Wire Ampacity Table

The following table outlines the derated ampacities for THHN wires of various sizes, based on 75°C ambient temperature. These values are intended for a single conductor and may require further derating for multiple conductors in a raceway or cable tray.

Always consult the NEC, local regulations, and the wire manufacturer's data sheets for specific advice tailored to your application.

THHN Wire Ampacity Chart (75°C Ambient Temperature)
Wire Gauge Conductor Size (mm²) Derated Ampacity (A)
6 0.15 10
8 0.30 13
10 0.5 16
12 0.8 20
14 1.2 24
16 1.6 30
18 2.0 35
20 2.6 42
22 3.14 50
24 4.1 57
26 5.1 67
30 7.1 85

Ampacities for THHN wires must also consider multiple conductors installed together. The NEC provides tables for derating THHN wire ampacity based on the number of current-carrying conductors in a raceway or cable tray. Be sure to consult these tables when installing THHN wire in bundled configurations.

several different types of wires are shown on a table with measurements for each type of wire
several different types of wires are shown on a table with measurements for each type of wire
different types of cable trays are shown in this graphic above it is an image of wire mesh trays
different types of cable trays are shown in this graphic above it is an image of wire mesh trays
the table shows the number and type of telephones
the table shows the number and type of telephones

Short Circuit and Ground-Fault Protection

Selecting THHN wire based solely on its ampacity might lead to insufficient Short Circuit and Ground-Fault Protection (SCGP). Always consider the Short Circuit Current Rating (SCCR) and Ground-Fault Protection Level (GFPL) of your electrical system when choosing THHN wire sizes.

Properly protecting your electrical system from damaging overloads and short circuits is crucial to maintain safety and prevent equipment failure.

In summary, choosing the right THHN wire size involves more than just selecting a wire based on its ampacity. Always consider the ambient temperature, specific application, and potential derating factors when selecting THHN wire for your project. Regularly consult the NEC, local regulations, and manufacturer's data sheets to ensure a safe and compliant electrical installation.

Stay informed and mitigate risks by staying up-to-date with the latest industry developments and best practices. Review the latest edition of the NEC, attend training courses, and engage with industry professionals to expand your knowledge of electrical safety.

💬 Comments ↗ Share ★ Save
AD