True or False: Grounding conductor in Rigid Metal Conduit?

By

When working with rigid metal conduit (RMC) in electrical wiring, one common query that often arises is whether a grounding conductor is indeed required. This question becomes especially crucial in light of the safety measures and standards that punctuate the world of electrical work. Let's delve into this topic, drawing insights from NEC guidelines and common electrical practices.

Before we dive deep, it's essential to grasp the purpose of a grounding conductor. A grounding conductor, or ground wire, is a critical component in an electrical circuit. Its primary objective is to provide a low-impedance path to the earth or a conductive mass, enhancing safety and ensuring the orderly operation of electric genera, motors, and other equipment.

The NEC Perspective on RMC and Grounding Conductors

The National Electrical Code (NEC), the standard for safe electrical wiring and equipment in the United States, offers clear guidelines on the use of grounding conductors with rigid metal conduit. According to NEC 250.118, when using RMC, a recognized means of equipment grounding must be provided and maintained.

Electrical Conduit
Electrical Conduit
an electrical panel with multiple wires attached to it
an electrical panel with multiple wires attached to it
How to Install Surface-Mounted Wiring and Conduit
How to Install Surface-Mounted Wiring and Conduit

Equipment Grounding with RMC

RMC, by its nature, acts as an effective ground conductor due to its metallic composition. However, NEC 250.118 necessitates a specific means of equipment grounding. This requirement emphasizes the importance of establishing a continuous, low-impedance ground path from the equipment to the grounding electrode system.

Some approved methods of equipment grounding with RMC include bonding the conduit to the equipment grounding conductor (EGC) at various intervals, using listed equipment protectors (EPs), or employing the parallel racing method (where a separate EGC is run beside and in contact with the RMC).

many pipes are lined up on the wall and hanging from the ceiling in order to be installed
many pipes are lined up on the wall and hanging from the ceiling in order to be installed
three people in blue work on electrical equipment at a construction site with brick walls behind them
three people in blue work on electrical equipment at a construction site with brick walls behind them
several types of electrical wires on a table
several types of electrical wires on a table

Bonding and Grounding Conductor sizes

NEC 250.122 outlines the size requirements for grounding conductors. For 120V, single-phase, 3-wire systems, the grounding conductor must be sized based on the circuit conductor's ampacity. ForSizes ranging from 14 to 10 AWG, the grounding conductor must be at least 14 AWG, and for conductors larger than 10 AWG, the grounding conductor must be at least 12 AWG.

Bonding, another necessary measure, involves connecting the RMC to the EGC at both the source and load ends, with additional bonds every 20 feet or where the conduit changes direction. These bonds ensure the continuity of the grounding path and mitigate the risk ofizarding and deterioration.

Alternatives to Using Rigid Metal Conduit

While RMC is an acceptable method for wiring, other types of conduit, such as flexible metallic tubing, may also be used. These alternative conduit types may have different grounding requirements, so it's crucial to familiarize yourself with the specific NEC guidelines for each.

two different types of electrical wiring for the home and office, with instructions on how to wire
two different types of electrical wiring for the home and office, with instructions on how to wire
Electrical Conduits - Fine Homebuilding
Electrical Conduits - Fine Homebuilding
pipes and piping in an industrial building
pipes and piping in an industrial building
a man is working on some electrical equipment
a man is working on some electrical equipment
1/2" x 10' ENT Conduit
1/2" x 10' ENT Conduit
an electrical box with some wires attached to it
an electrical box with some wires attached to it

Flexible Metallic Tubing (FMT)

Unlike RMC, FMT does not provide an effective ground path, necessitating the use of a separate EGC. NEC 300.11 requires that FMT be approved for use as an EGC, and it must be bonded at both the source and load ends, with intermediate bonds every 10 feet.

Moreover, due to the risk of kinking and fanning, which can compromise the electrical continuity and reliability of the grounding path, FMT requires additional attention during installation.

Conduit-Body Grounding

Conduit-body grounding is another method of establishing a ground path, where the non-current-carrying metal parts of a piece of equipment are connected directly to theEnumerable earth or a grounding electrode. This method can be used with various conduit types, including RMC, and is particularly useful when the equipment is mounted outdoors.

a drawing of different types of pipes and fittings on a piece of lined paper
a drawing of different types of pipes and fittings on a piece of lined paper
Rigid And Intermediate Conduit Fittings
Rigid And Intermediate Conduit Fittings

However, conduit-body grounding should not replace the use of an EGC, as it does not provide protection against indirect faults. Therefore, it's essential to use both methods in conjunction, as outlined in NEC 250.142.

In the dynamic world of electrical work, understanding the necessity of grounding conductors when using RMC is not just beneficial; it's imperative. As the saying goes, "an ounce of prevention is worth a pound of cure," and in the context of electrical safety, this statement rings louder than ever. Always ensure you're up-to-date with the latest NEC guidelines, and never hesitate to seek expert advice when in doubt.

💬 Comments ↗ Share ★ Save
AD