Ampacity, a term deriving from 'ampere' and 'capacity', refers to the maximum amount of current an electrical cable can safely carry without exceeding its insulation rating or causing damage. When it comes to utilizing two cables in parallel - which is a common practice in high load scenarios - the question of how to calculate their combined ampacity often arises. This article explores the use of 2 cable ampacity and guides you through the process.

Before diving into the specifics, let's understand why two cables might be used instead of one. In high current applications, such as powering large motors or feeding high-demand circuits, a single cable might not have sufficient ampacity. By connecting two cables in parallel, their ampacities combine, allowing for higher current flow.

Understanding Parallel Cable Ampacity

When two cables are used in parallel, their ampacities add up. For instance, if each cable has an ampacity of 50 amps (A), then two of them in parallel can safely carry 100A, given all other factors remain constant.

Aluminum cable ampacity chart: Everything You Need To Know
Aluminum cable ampacity chart: Everything You Need To Know
an electrical wiring diagram with several wires labeled in the following words, including cable - twisted pair and jacked pair
an electrical wiring diagram with several wires labeled in the following words, including cable - twisted pair and jacked pair
two red and blue wires connected to each other in the middle of an electrical cable
two red and blue wires connected to each other in the middle of an electrical cable

However, while the calculation is seemingly straightforward, other factors influence the total ampacity when using two cables in parallel.

Cable Size and Gauge

Cable size or gauge plays a significant role in determining ampacity. Larger cables (e.g., 10 AWG, 8 AWG, 6 AWG) have higher ampacity ratings than smaller ones (e.g., 14 AWG, 12 AWG, 10 AWG).

electric arc energy discharge spark between two cables
electric arc energy discharge spark between two cables
Conductor Ampacity, Voltage Drop, and Line Losses Explained | Electrical Academia
Conductor Ampacity, Voltage Drop, and Line Losses Explained | Electrical Academia
COK-2
COK-2

But what if you're using two cables of different sizes? A common misconception is to simply add their ampacities. Instead, you should use the smaller cable's ampacity as the limiting factor, per NEC (National Electrical Code) rules.

Ambient Temperature

Higher ambient temperatures lower a cable's ampacity. This is because heat reduces insulation effectiveness. Both cables in parallel are exposed to the same ambient temperature, so use the lower ampacity rating for the two cables combined.

For example, if two 50A cables have an ambient temperature rating of 90°C and 105°C respectively, you would use the 90°C rating for both cables in parallel, resulting in a total ampacity of 50A, not 100A.

Electrical Wire & Cable Sizes with Current Rating ⚡ Cheat Sheet for Safe Wiring Guide
Electrical Wire & Cable Sizes with Current Rating ⚡ Cheat Sheet for Safe Wiring Guide
Agency Spotlight: AAARep – Artists' Blogs
Agency Spotlight: AAARep – Artists' Blogs
the differences between every cable type
the differences between every cable type
A network cable connected to two connectors
A network cable connected to two connectors
where ampere
where ampere
HOW TO TWIST ELECTRIC WIRE TOGETHER. Properly Joint Electrical Wire.
HOW TO TWIST ELECTRIC WIRE TOGETHER. Properly Joint Electrical Wire.

Practical Considerations

So far, we've discussed theoretical aspects. Now let's delve into practical considerations when using two cables in parallel.

Firstly, ensure both cables share the same current path. This means they should run parallel for their entire length and terminate together. If one cable takes a different path or has a different length, it could cause current imbalances and overheating.

Connecting the Cables

When connecting two cables in parallel, it's crucial to ensure they have the same voltage and are of the same type (twisted, flat, etc.). Connecting a 12V cable to a 24V one could cause damage or ignition. Use appropriate bus bars or nobs and bolts to connect both cables' bare wires securely.

To avoid current imbalance, ensure both cables have equal resistance. This could mean using lengths that are as identical as possible or compensating with additional wire in the shorter cable.

Measuring Combined Ampacity in Practice

While the calculations give a good indication, it's always a good idea to test the combined ampacity of your two cables. This is best performed using a clamp meter, which measures current without disconnecting the cable.

To test, gradually increase the current load until the cable temperature reaches the maximum allowable limit for the ambient temperature (usually marked on the cable's insulation). Remember to consider any additional factors, such as load losses and I2R losses, which can cause cables to heat up even without any load.

In the end, while using two cables in parallel can increase your system's ampacity, always remember that safety remains paramount. Follow the guidelines laid out in the NEC and other relevant codes, and always double-check your calculations and installations.

💬 Comments ↗ Share ★ Save
AD