What's the Distinction: Order Block vs. Breaker Block
In the world of electrical engineering and programming, two terms often mentioned are "order block" and "breaker block." Both play vital roles in control systems, but they serve distinct purposes and have different functionalities. This article delves into the key differences between the two, ensuring you understand these critical components in control system design.
Before diving into the differences, let's briefly understand each term. An order block, also known as an output block, is responsible for controlling an output device, such as a valve or a motor, based on the input signals it receives. On the other hand, a breaker block is a protective device that monitors the system's current and opens the circuit when it detects an overcurrent condition, safeguarding the system from potential damage or hazards.
Understand the Functionality
The primary function of an order block is to control the output device based on the input signals. It takes the input signals, processes them, and then triggers the output device accordingly. For instance, in a heating system, an order block might receive a temperature setpoint as an input signal and then activate the heating element when the current temperature is below the setpoint.
In contrast, a breaker block's primary purpose is to protect the system and the devices within it from overcurrent conditions. It continuously monitors the current flowing through the circuit and breaks the circuit when the current exceeds a predefined limit, preventing potential damage or hazards, such as fire or electrical shock.
Input and Output Signals
The input to an order block can vary widely depending on the system's requirements, from simple on/off signals to complex logic or mathematical calculations. The output, likewise, can be a simple on/off signal or a complex combination of signals that control the output device.
On the other hand, a breaker block typically doesn't have an 'input' as such. Instead, it monitors the current flowing through the circuit, with the 'input' being the actual current passing through the protected circuit. The 'output' of a breaker block is a simple on/off signal thatEither opens or closes the circuit, depending on whether an overcurrent condition is detected.
Re-setting and Reset Delay
Another key difference lies in how these blocks respond to overcurrent conditions. Order blocks, which control output devices, might also have an inbuilt overcurrent protection function. However, if an overcurrent condition occurs, these blocks usually require reset to resume normal operation. Some blocks may have a fixed reset delay to prevent rapid toggling between open and closed states, which could be damaging to the output device.
Conversely, breaker blocks, designed for protection, often have auto-reclosing and delayed reclosing features. After tripping due to an overcurrent, a breaker block can automatically reset or wait for a specific time (delayed reclosing) before attempting to reclose the circuit. This helps in protecting the system from subsequent overcurrent conditions until the issue causing the overcurrent is resolved.
The Place in Control System Hierarchy
Order blocks are usually part of the main control loop in a system. They receive the control signal (like a setpoint for temperature control), process it, and then drive the output device to achieve the desired control objective. Their placement in the control hierarchy is typically under the logic decision-making entity and above the output device.
Breaker blocks, on the other hand, are usually inserted into the circuit to protect specific components or the entire system. They can be placed anywhere in the hierarchy where protection is necessary, above the device they are protecting, and sometimes parallel to it. Notably, they are not usually part of the main control loop, but rather an auxiliary protective mechanism.
Interaction with Other Blocks
Order blocks often interact with other control blocks, like PID (Proportional-Integral-Derivative) controllers or logic blocks, to receive the control signal that triggers the output device. They may also include interlocks or safety functions that disable the output when certain conditions are met, such as an emergency stop signal.
Breaker blocks, however, primarily interact with the current sensors that monitor the current in the protected circuit. They may also communicate with the control system to report the status of the protected device or trigger an alert when an overcurrent condition is detected. For high-level protection of the entire system, breaker blocks may interact with the main control entity, such as a Programmable Logic Controller (PLC) or a Distributed Control System (DCS).
Understanding the difference between order blocks and breaker blocks is crucial for designing and maintaining safe and effective control systems. By understanding their unique functionalities and places in the control system hierarchy, one can ensure the reliable operation and protection of the system and its components. Therefore, consider these key differences when designing and troubleshooting your next electrical or automation system.