What Size Aluminum Cable for 100 Amps

By

Choosing the right aluminum cable size for a 100 amp circuit requires careful consideration of factors such as voltage drop, conduit fill, and ampacity. Aluminum conductors are an excellent choice due to their affordability, light weight, and high conductivity. However, they must be properly sized to ensure safety and reliability.

Aluminum conductor sizes are denoted by their American Wire Gauge (AWG) numbers, which inversely relate to their cross-sectional area. The larger the AWG number, the smaller the wire. To determine the proper size for a 100 amp circuit, we must consider the maximum allowable voltage drop and ampacity of aluminum wire.

Aluminum Wire Ampacity Tables

Table 1: AMPacity of Aluminum Conductors for 75°C

What Size of Wire Do I Need for a 100 Amp Sub Panel?
What Size of Wire Do I Need for a 100 Amp Sub Panel?
What is the Right Wire Size for 100-Amp Service Panel?
What is the Right Wire Size for 100-Amp Service Panel?
Wire Size For 100 Amp Service 150 Feet
Wire Size For 100 Amp Service 150 Feet

The NEC (National Electrical Code) provides tables of allowable ampere ratings (ampacity) for nonheat-generating (Type NCH) and heat-generating (Type NHH) loads at 90°C. For most residential and commercial applications, the temperature rating is typically 75°C, which offers a derate factor of 0.9.

Non-Heat-Generating (NCH) Loads

The ampacity of an aluminum conductor for NCH loads can be found in Table 1 of the NEC. For a 100 amp circuit, a #2 aluminum conductor (Aluminum 2/0) would be needed. This size has an ampacity of 130 amps under 75°C with consideration to derating. Keep in mind that this size can only be used if the rated ampacity is not exceeded and the voltage drop remains within acceptable limits.

the table shows the number and type of electrical codes for various types of installations
the table shows the number and type of electrical codes for various types of installations
Cable Lug Size List
Cable Lug Size List
the industrial cable size chart is shown
the industrial cable size chart is shown

Voltage drop in an electrical circuit is the difference between the supply voltage and the voltage at the load. The NEC limits voltage drop to 3% at the maximum load for most applications, but some critical loads may require less than 1%.

Heat-Generating (NHH) Loads

For NHH loads, refer to Table 2 of the NEC. If you're dealing with a heat-generating load such as a water heater or oven, use Table 2 to find that the #4 aluminum conductor (Aluminum 4/0) has an ampacity of 175 amps under 75°C with consideration to derating. However, you would need to consult with a professional to ensure the voltage drop and other factors remain within acceptable limits.

Voltage Drop Calculation

To calculate voltage drop, you'll need to know the voltage of the circuit (often 120V or 240V), the length of the conductor, and the current (amps) it will be carrying. Use the formula: Voltage Drop = (Amps x Distance x Resistivity) / Conductor Size. This will give you the voltage drop in volts. To find the percentage voltage drop, divide by the circuit voltage and multiply by 100.

Cable Size Selection
Cable Size Selection
the size and measurements for cable sizes
the size and measurements for cable sizes
OSCP & Superhero League: SCVeloutesc's Jogja Adventure
OSCP & Superhero League: SCVeloutesc's Jogja Adventure
the size and length of wires are shown in this graphic above which wire sizes do you need to use?
the size and length of wires are shown in this graphic above which wire sizes do you need to use?
Cable Lug Types Guide | Copper, Aluminum & Bimetal Terminals Explained | YOMIN Electric
Cable Lug Types Guide | Copper, Aluminum & Bimetal Terminals Explained | YOMIN Electric
Electrical Wire & Cable Sizes with Current Rating ⚡ Cheat Sheet for Safe Wiring Guide
Electrical Wire & Cable Sizes with Current Rating ⚡ Cheat Sheet for Safe Wiring Guide

Conductor Resistivity

The resistivity of aluminum is around 2.82 nΩ·m at 20°C. This value can be used for voltage drop calculations. Keep in mind that resistivity changes with temperature, so you may need to use a different value for high-temperature applications.

For example, if you're running a #2 aluminum conductor (Aluminum 2/0, awg=2) for 100 feet to supply a 100 amp load at 240V, your voltage drop would be approximately 2.3%. This is well within the NEC's 3% limit for non-critical loads.

Remember, these calculations are simplified and do not account for factors such as ambient temperature, conduit fill, or derating for parallel conductors. Always consult the NEC and any relevant local codes when sizing conductors.

Cable size &rating
Cable size &rating
What Size Cable For Amp
What Size Cable For Amp

Properly sizing aluminum cable for a 100 amp circuit is crucial for ensuring safe, reliable, and code-compliant electrical service. When in doubt, consult with a licensed electrician or electrical engineer. In the world of electrical contracting, precision in wire sizing can prevent costly mistakes and potential hazards.