▲Wirig Diagram Hot
▲ ▲ ▼

Perfect Armoured Cable Sizes for Summerhouses

By

Choosing the right size of armoured cable for your summerhouse is crucial for both safety and functionality. With many sizes and types available, it can be challenging to select the most suitable one. This guide will help you understand what you need to consider when choosing the right armoured cable for your summerhouse.

Armoured cables are designed to protect internal wires from damage caused by environmental factors, vibrations, and other harsh conditions. They are essential for outdoor settings like summerhouses, providing power to lighting, appliances, and other equipment.

Understanding Armoured Cables

Before diving into cable sizes, it's essential to understand the different types of armoured cables to ensure you choose the right one for your needs.

What Size Wire to Run to a Shed?
What Size Wire to Run to a Shed?
758K views • 7.6K likes | Reel by Maa Khodal Electrician
758K views • 7.6K likes | Reel by Maa Khodal Electrician
The Idea Behind Shielded Cables
The Idea Behind Shielded Cables

There are two primary types of armoured cables: steel wire armoured (SWA) cables and liquid-filled (or low fire hazard) armoured cables. SWA cables are typically used for outdoor installations due to their robust protection and are suitable for summerhouses. Liquid-filled cables, on the other hand, are designed for use in hazardous areas such as mines and petrochemical plants and are not usually required for summerhouse installations.

Steel Wire Armoured (SWA) Cables

SWA cables consist of an insulated conductor surrounded by a layer of steel tapes or steel wires, followed by a sheath. This construction provides exceptional mechanical protection, making SWA cables an excellent choice for outdoor applications in summerhouses.

the cable size comparison chart for each type of wire, which is shown above and below
the cable size comparison chart for each type of wire, which is shown above and below
some blue wires are connected to the inside of an unfinished room with wood framing and walls
some blue wires are connected to the inside of an unfinished room with wood framing and walls
the cable size guide for cables and gland sizes is shown in this image
the cable size guide for cables and gland sizes is shown in this image

SWA cables are available in various designs, including:

  • Single-core: A single conductor surrounded by armour.
  • Three-core: Three conductors twisted together and armoured collectively.
  • Multi-core: Multiple conductors, each with its own armour, twisted together.

Choosing the Right Armour Type

Most SWA cables for summerhouses use galvanised steel tape armour, which provides good corrosion resistance. However, you may also encounter SWA cables with a lead sheath or aluminium armour. Galvanised steel tape is the most common and suitable for most summerhouse applications.

For areas exposed to harsh environments or salt mist, you might consider SWA cables with enhanced corrosion resistance, such as those with aluminium armour or an additional outer sheath.

the table shows how many different cable sizes are available
the table shows how many different cable sizes are available
How To Power Your Shed Or Garden Office In The Uk - Shedblog
How To Power Your Shed Or Garden Office In The Uk - Shedblog
Specialised Wiring Accessories
Specialised Wiring Accessories
Electrical Wire & Cable Sizes with Current Rating ⚡ Cheat Sheet for Safe Wiring Guide
Electrical Wire & Cable Sizes with Current Rating ⚡ Cheat Sheet for Safe Wiring Guide
an image of the inside of a house with all its components labeled in english and german
an image of the inside of a house with all its components labeled in english and german
table size chart for cable sizes
table size chart for cable sizes

Determining the Correct Armoured Cable Size

Once you've chosen the type of SWA cable, the next step is to select the appropriate size based on your summerhouse's power requirements and circuit protection.

All SWA cables are designated using a code consisting of three parts: the cross-sectional area of the conductors (in square millimetres), the number of conductors, and the type of armour. For example, a 6mm² SWA cable with three cores would be designated as "3 x 1.5mm² SWA."

Calculating Power Requirements

To determine the total power requirement for your summerhouse, list all the appliances and lighting fixtures you plan to use and multiply each one's wattage by the number of appliances. For example, if you have four 60W light bulbs and one 1,000W heater, your total power requirement would be:

the size and measurements for cable sizes
the size and measurements for cable sizes
Armoured Cable Gland Sizes and Advice Guide
Armoured Cable Gland Sizes and Advice Guide

4 x 60W + 1,000W = 1,260W

Choosing the Correct Circuit Protector

Now that you know the total power requirement, you can select the appropriate circuit protector (fuse or circuit breaker) based on the current rating. To find the current rating, divide the total power requirement by the supply voltage:

Current rating = Total power requirement (W) / Supply voltage (V)

For a typical 230V supply, using a 1,260W load:

Current rating = 1,260W / 230V ≈ 5.5A

In this case, you would need a 16A fuse or circuit breaker to protect your summerhouse's electrical circuit.

Selecting the Right Cable Size Based on Circuit Protector

Now that you have the correct fuse or circuit breaker, you can select the appropriate SWA cable size. Armoured cables are typically rated for a specific current-carrying capacity (ampacity) based on their cross-sectional area and construction.

Using tables provided in BS 7846 or other relevant standards, you can find the suitable SWA cable size for your chosen circuit protector. For a 16A (16.33A) circuit protector, you can select between a 4mm² or 6mm² SWA cable, depending on the length of the cable run and its layout. Longer runs or more complex layouts may require a larger cable size.

In summary, choosing the right size of armoured cable for your summerhouse involves understanding the types of armoured cables, determining your power requirements, selecting the appropriate circuit protector, and finally, selecting the suitable cable size based on the protector's rating and the cable's specified ampacity. Always refer to relevant standards and regulations when selecting electrical equipment and ensure that your installation complies with local electrical codes.