What Size Service Cable for 100 Amp Sub Panel?

By

When upgrading or adding a 100-amp sub panel to your electrical system, it's crucial to size the service cable correctly to ensure safety and compliance with electrical codes. The service cable, also known as the feeder, connects the main panel to the sub panel, delivering power from the source to the new electrical circuit.

To determine the suitable cable size, you must consider the circuit's load, the voltage drop, and adhere to the National Electrical Code (NEC). The biggest misconception is that a 100-amp sub panel requires a 100-amp breaker and cable. However, the reality is more complex and depends on various factors.

Understanding Ampacity and Circuit Load

Before selecting a service cable, it's essential to understand the concept of ampacity and circuit load. Ampacity refers to a wire's ability to carry current safely without exceeding its insulation rating. The circuit load, on the other hand, is the total amount of current drawn by all connected devices simultaneously at their maximum capacity.

Wire Size For 100 Amp Service 150 Feet
Wire Size For 100 Amp Service 150 Feet
Upgrade electrical service from 100 amps to 200 amps
Upgrade electrical service from 100 amps to 200 amps
the size and measurements for an amp speaker with different types of speakers in each section
the size and measurements for an amp speaker with different types of speakers in each section

A 100-amp sub panel can serve circuits with a combined load of up to 100 amperes. However, it's not advisable to have all circuits operating at their maximum capacity simultaneously. Thus, it's crucial to size the service cable based on the total expected load and follow NEC guidelines.

NEC Requirements for Feeder Cables

The NEC provides guidelines for selecting feeder cables based on the circuit's uninterrupted load, voltage, and the maximum allowable voltage drop. For a 100-amp sub panel, the most common and practical feeder cable sizes are #2, #3, and #4 Non-Metallic (NM) or #6, #8, and #10 Aluminum (AL) and copper (CU) conductors.

the industrial cable size chart is shown
the industrial cable size chart is shown
Sub Panel Wire Size Calculator – Accurate Wire Gauge & Load Sizing Tool
Sub Panel Wire Size Calculator – Accurate Wire Gauge & Load Sizing Tool
the size and length of wires are shown in this graphic above which wire sizes do you need to use?
the size and length of wires are shown in this graphic above which wire sizes do you need to use?

Here's a table illustrating the minimum feeder cable sizes for a 100-amp sub panel, based on NEC 2020 and considering a 3% voltage drop:

Cable Type Cable Size Maximum Load (Amperes)
NM Non-Metallic #2 90
NM Non-Metallic #3 110
NM Non-Metallic #4 130
AL or CU Aluminum/Copper #6 105
AL or CU Aluminum/Copper #8 125
AL or CU Aluminum/Copper #10 140

Factors Affecting Service Cable Selection

Several factors can influence the choice of service cable for a 100-amp sub panel. These include:

Circuit Load

Accurately calculating the combined load of all circuits connected to the sub panel is crucial. If the total load exceeds the cable's ampacity, it could cause overheating, insulation damage, and potential fire hazards.

How to Install and Wire a Sub-Panel
How to Install and Wire a Sub-Panel
an electrical wiring diagram for a home
an electrical wiring diagram for a home
Cable Lug Size List
Cable Lug Size List
an electrical wiring diagram for a home
an electrical wiring diagram for a home
How to Wire a Subpanel? Main Lug Installation for 120V/240V
How to Wire a Subpanel? Main Lug Installation for 120V/240V
What wire type & size for sub-panel in a shed?
What wire type & size for sub-panel in a shed?

To size the feeder cable, consider the continuous load (ampere) rating of each circuit breaker connected to the sub panel. Add up these ratings to determine the total circuit load and compare it with the cable's ampacity.

Voltage Drop

Voltage drop occurs when electricity is conducted through a wire, causing a decrease in voltage from the source to the load. Excessive voltage drop can affect the performance of electrical appliances and circuits.

The NEC permits a 3% or 5% voltage drop, depending on the circuit and application. Sizing the feeder cable based on the voltage drop ensures safe and efficient power delivery to the electrical loads.

How to install a sub panel. 100 amp sub panel quick and easy
How to install a sub panel. 100 amp sub panel quick and easy
the cable size chart for an electrical device, with different colors and sizes to choose from
the cable size chart for an electrical device, with different colors and sizes to choose from
100 amp Attached Garage Sub Plan
100 amp Attached Garage Sub Plan

Properly sizing the service cable for a 100-amp sub panel is critical for a safe and reliable electrical system. By following NEC guidelines, considering the circuit load, and understanding the impact of voltage drop, you can select the appropriate cable size for your specific needs. Consult with a licensed electrician if you're unsure about the proper cable size or have any questions about your electrical system.