When planning to install a 100-amp subpanel 20 feet away from your main panel, one critical aspect you shouldn't overlook is the appropriate wire size. Using the correct gauge ensures safety, reliability, and adherence to National Electrical Code (NEC) regulations.

Before we dive into the specific wire gauges, let's briefly understand why the distance between your main panel and subpanel matters. Electrical resistance causes voltage drop in wires, leading to decreased performance. Thus, a greater distance requires larger wires to mitigate this drop.

Understanding Wire Gauge for Subpanels

In electrical work, wire gauge refers to the American Wire Gauge (AWG) size system. Lower AWG numbers indicate larger wire diameters and higher current-carrying capacities.

What is the Right Wire Size for 100-Amp Service Panel?
What is the Right Wire Size for 100-Amp Service Panel?
100 amp Attached Garage Sub Plan
100 amp Attached Garage Sub Plan
What Wire Size For 100 Amp Sub Panel That's 200 Feet Away? (Safety Precautions)
What Wire Size For 100 Amp Sub Panel That's 200 Feet Away? (Safety Precautions)

For a 100-amp subpanel, you'll need to feed it with at least a 100-amp breaker at the main panel. Thus, your wire must support at least 100 amps to safely carry power from the main panel to the subpanel.

Feeder Wire Sizes

For a 20-foot run between the main panel and a 100-amp subpanel, the most common wire sizes are 6 AWG, 4 AWG, and 2 AWG. Each size has a specific maximum allowable ampacity as per the NEC, with larger gauges supporting more amps.

Installing 100 Amp Service Wire To Work Shop
Installing 100 Amp Service Wire To Work Shop
How to Wire a Subpanel? Main Lug Installation for 120V/240V
How to Wire a Subpanel? Main Lug Installation for 120V/240V
What Size Wire for 50 Amp? Exact Gauge Guide for Safe & Code-Compliant Wiring
What Size Wire for 50 Amp? Exact Gauge Guide for Safe & Code-Compliant Wiring
  • 6 AWG - Supports up to 65 amps. Suitable if your subpanel's total load won't exceed 65 amps, but it's often used for future-proofing installations.
  • 4 AWG - Supports up to 75 amps. A common choice for 100-amp subpanels, offering some headroom for future demand and minor voltage drops.
  • 2 AWG - Supports up to 140 amps. Ideal for long runs or high-demand loads. Gives you plenty of capacity and headroom for future expansion.

Wire Type

Another crucial factor is choosing the right wire type. Non-metallic (NM) or rope-style cables are typically used for branch circuits within homes, but for feeder wires between panels, you'll need something more robust.

  • THHN/THWN - Thermoplastic High Heat Rated Nylon/Waterproof Nylon wires areолевка widely used for feeder applications. They're covered in a durable, moisture-resistant jacket, making them suitable for both interior and exterior runs.
  • MC Cable - Metal-Clad cables have a thick, flexible jacket filled with voids for gas and water in case of arc flash events. They're commonly used for high-amperage and long runs but are more expensive than THHN/THWN.

Before finalizing your wire choice, consult with a licensed electrician or local electrical inspector to ensure compliance with local codes and regulations. They can provide tailored advice based on your specific situation.

Calculating Voltage Drop

To further ensure your wire size is appropriate, calculate the expected voltage drop. Voltage drop increases electrical resistance and reduces the power available at the end of the circuit.

What wire type & size for sub-panel in a shed?
What wire type & size for sub-panel in a shed?
Installing A Electrical Sub Panel
Installing A Electrical Sub Panel
What Size Wire for 30 Amps 200 Feet (Tips & Recommendation)
What Size Wire for 30 Amps 200 Feet (Tips & Recommendation)
How to wire and properly ground a 30 Amp sub-panel
How to wire and properly ground a 30 Amp sub-panel
How to Install and Wire a Sub-Panel
How to Install and Wire a Sub-Panel
What Wire Size For 100 Amp Sub Panel That's 200 Feet Away?
What Wire Size For 100 Amp Sub Panel That's 200 Feet Away?

A generally accepted voltage drop limit is 3% for branch circuits and 5% for feeder circuits. If the calculated voltage drop exceeds these limits, you may need to upsize your wire or consider using a larger breaker at the main panel.

Using the Voltage Drop Formula

The voltage drop formula is:

V=I * L *R
Voltage Drop (V)Current (I)Resistance (R)

Where:

Sub Panel Wiring Diagram and Connection with Main Panel
Sub Panel Wiring Diagram and Connection with Main Panel
What Size Wire for 50 Amps (A Handy Guide)
What Size Wire for 50 Amps (A Handy Guide)
  • I = Current in amps
  • L = Wire length in feet
  • R = Resistor for the wire size (available in reference materials or NEC Table 8)

With a 20-foot run, a 4 AWG THHN/THWN wire, and a 100-amp load, you can expect a voltage drop below 3%. However, always double-check these calculations to stay within NEC compliance.

In conclusion, for a 100-amp subpanel 20 feet from the main panel, consider 4 AWG or 2 AWG THHN/THWN wires to ensure safety and compliance with NEC regulations. Always consult a professional electrician before making final decisions or starting any electrical work.