▲Wirig Diagram Hot
▲ ▲ ▼

What Size Wire for 20 Amp Circuit at 100 Feet

By

When it comes to electrical wiring, understanding the correct wire size for a given circuit is paramount. This ensures safety, efficiency, and longevity of your electrical installations. Today, we delve into the crucial question, "What size wire for a 20 amp circuit 100 feet?" Let's demystify this query step by step.

'Why is wire size essential?' you might ask. It's simple: ampacity. Wire size determines the maximum current a wire can safely carry, known as its ampacity. For a 20-amp circuit, your wire must have an ampacity rating of at least 20 amps to avoid overheating and potential hazards.

Understanding Wire Gauges

Electrical wiring comes in various gauges, or American Wire Gauges (AWG), ranging from 0000 to 40. Smaller the gauge number, larger the wire diameter. To determine the suitable wire size for a 20-amp, 100 feet circuit, we must first understand these wire gauges.

What is the Right Wire Size for 100-Amp Service Panel?
What is the Right Wire Size for 100-Amp Service Panel?
What Size Wire to Run to Shed?
What Size Wire to Run to Shed?
the size and length of wires are shown in this graphic above which wire sizes do you need to use?
the size and length of wires are shown in this graphic above which wire sizes do you need to use?

Here's a quick reference of common wire sizes and their ampacities:

  • 14 AWG: 15 Amps
  • 12 AWG: 20 Amps
  • 10 AWG: 30 Amps
  • 8 AWG: 44 Amps
  • 6 AWG: 62 Amps

12 AWG: The Optimal Choice

For a 20-amp circuit, a 12 AWG wire is typically the best option. It has an ampacity of 20 amps, exactly what you need. Moreover, it offers some wiggle room for future upgrades or heavier loads, as it's designed not to exceed 20 amps under normal conditions.

Circuit Breaker Sizes Explained 2026: With Charts
Circuit Breaker Sizes Explained 2026: With Charts
an info poster showing different types of wires
an info poster showing different types of wires
WHAT SIZE WIRE FOR 20 AMP CIRCUIT? - The Engineering Knowledge
WHAT SIZE WIRE FOR 20 AMP CIRCUIT? - The Engineering Knowledge

cautioned, however, as 12 AWG wire may not be suitable for longer runs due to voltage drop. A 100-foot circuit could potentially experience significant voltage drop due to its length. Therefore, it's recommended to use a larger gauge, such as 10 or 8 AWG, for longer runs despite their higher ampacity.

Adjusting for Longer Runs

To mitigate voltage drop over long distances, you can choose a larger gauge wire. For instance, a 10 AWG wire has an ampacity of 30 amps but can safely carry 20 amps over a 100-foot run with minimal voltage drop. Meanwhile, an 8 AWG wire can maintain near-full voltage over even longer distances.

However, be mindful of your circuit protective devices (such as fuses or circuit breakers). They must be compatible with the wire size you've chosen. Always follow local codes and consult a licensed electrician if you're uncertain.

electrical wire sizes and ampity table with instructions for different types of wires on it
electrical wire sizes and ampity table with instructions for different types of wires on it
Circuit Breaker & Wire Size Compatibility Guide: Amperage & Gauge Chart.
Circuit Breaker & Wire Size Compatibility Guide: Amperage & Gauge Chart.
Wire Size Calculator: Find the Right Wire Gauge for Your Project
Wire Size Calculator: Find the Right Wire Gauge for Your Project
the different types of electrical wires are labeled in this diagram, which is what they look like
the different types of electrical wires are labeled in this diagram, which is what they look like
What Size Wire for 30 Amps 200 Feet (Tips & Recommendation)
What Size Wire for 30 Amps 200 Feet (Tips & Recommendation)
the measurements for different types of wire sizes
the measurements for different types of wire sizes

Factors Affecting Wire Size

Beyond ampacity, several factors influence wire size selection. These include voltage, length of the run, ambient temperature, and environmental conditions. Let's discuss voltage drop, a critical factor in long circuits.

Voltage drop occurs when current flows through a wire, causing a small decrease in the voltage at the end of the circuit. This is acceptable within limits but can cause issues with sensitive electronics or appliances. In such cases, a larger wire may be necessary, even if the ampacity is greater than needed.

Conduit or Open Wiring?

Whether you're using conduit, open wiring, or another method influences your wire size decision. Conduit protects wires from external elements but can restrict airflow, causing wires to run hotter. Therefore, you might need to increase the wire size when using conduit.

Electrical wire size & load conversation chart
Electrical wire size & load conversation chart
the cable size chart for an electrical device, with different colors and sizes to choose from
the cable size chart for an electrical device, with different colors and sizes to choose from

Open wiring, on the other hand, offers better airflow but exposes wires to environmental hazards. Here, your wire size primarily depends on ampacity, length, and voltage drop, with additional considerations for environmental factors.

In conclusion, for a 20-amp circuit spanning 100 feet, start with a 12 AWG wire. If voltage drop becomes an issue, consider stepping up to 10 or 8 AWG. Always inspect your installation, follow local codes, and consult a professional if unsure. Regular maintenance and upgrades ensure your wiring system stays reliable, safe, and efficient over time.