Wire Size Chart MM2

By

When working with electrical systems, selecting the appropriate wire size is crucial for safe and efficient operation. This is where a wire size chart in mm² comes in handy. These charts help you determine the correct wire gauge based on factors such as current rating, voltage, and environmental conditions.

Understanding a wire size chart in mm² involves knowing that the unit 'mm²' refers to the cross-sectional area of the conductor. The larger the cross-sectional area, the greater the current-carrying capacity of the wire. This chart is particularly useful in European and many international contexts, as it's based on the European standard, IEC 60228.

Understanding a Wire Size Chart in mm²

A wire size chart in mm² typically presents a table with columns for the wire gauge size, current rating, voltage, and insulation. The wire gauge size is usually its numerical value, while the current rating indicates the maximum current that can flow through the wire without causing it to overheat.

Electrical Wire & Cable Sizes with Current Rating ⚡ Cheat Sheet for Safe Wiring Guide
Electrical Wire & Cable Sizes with Current Rating ⚡ Cheat Sheet for Safe Wiring Guide
Copper Wire Size Chart awg/swg: All You need to Know in mm or Inches
Copper Wire Size Chart awg/swg: All You need to Know in mm or Inches
MM2 to AWG - Wire Size Conversion Chart, Table, & Calculator [PDF]
MM2 to AWG - Wire Size Conversion Chart, Table, & Calculator [PDF]

For example, a wire with a size of 2.5 mm² might have a current rating of 16 A at 70°C and 20 A at 0°C, meaning it can safely carry 16 amps at 70°C ambient temperature and 20 amps at 0°C.

Current Rating vs. Voltage

The current rating is more crucial than voltage when selecting a wire size. A wire's current rating is determined by its cross-sectional area (mm²) and the thermal properties of the conductor material. Therefore, wires with larger cross-sectional areas have higher current ratings.

Electrical wire size & load conversation chart
Electrical wire size & load conversation chart
| Learn Electrical Engineering
| Learn Electrical Engineering
Wire Gauge to mm – The Jewellery Maker’s Guide (UK/AU Gauge System)
Wire Gauge to mm – The Jewellery Maker’s Guide (UK/AU Gauge System)

Voltage, on the other hand, does not determine the wire size. It's the current that heats the wire, not the voltage. So, a wire's size isn't determined by the voltage it carries, but rather by the current it needs to carry safely.

Insulation and Environmental Conditions

Wire insulation is also a critical factor. Different types of insulation have different current-carrying capacities based on the material's thermal properties. For instance, PVC (Polyvinyl Chloride) insulation has a lower current-carrying capacity compared to TPE (Thermoplastic Elastomer) or XLPE (Cross-Linked Polyethylene).

Environmental conditions also play a role. Wires in areas prone to high temperatures or exposed to direct sunlight might need to be a larger size than those in cooler, shaded areas to ensure they don't overheat and fail.

the table shows how many different types of electrical equipment are available for each type of device
the table shows how many different types of electrical equipment are available for each type of device
the cable size chart for an electrical device, with different colors and sizes to choose from
the cable size chart for an electrical device, with different colors and sizes to choose from
the industrial cable size chart is shown
the industrial cable size chart is shown
American Wire Gauge (AWG) Sizes and Properties Chart / Table
American Wire Gauge (AWG) Sizes and Properties Chart / Table
AWG/SWG to mm/mm2, inch/inch2 & kcmil Calculator & Conversion
AWG/SWG to mm/mm2, inch/inch2 & kcmil Calculator & Conversion
an electrical calculator with the text how to calculate cable size mm2 for 3 phase
an electrical calculator with the text how to calculate cable size mm2 for 3 phase

Using a Wire Size Chart in mm²

To use a wire size chart in mm², first, determine the total current that will flow through the wire based on the connected load's power rating (in watts) and the supply voltage. Then, use this current to find the appropriate wire size from the chart's current rating column.

Here's an example: If you're connecting a 2000 W (2 kW) load to a 230 V supply, the current is 2000 W / 230 V = 8.7 A. From the chart, you'd see that a 4 mm² wire has a current rating of 18.9 A (at 70°C), so it would be a suitable choice for this application.

Overrating and Underrating Wires

It's generally best to 'overrate' wires, using a larger size than the calculated minimum. This provides a safety margin and ensures that the wire won't overheat even under maximum load or adverse conditions.

Wire Size Calculator: Find the Right Wire Gauge for Your Project
Wire Size Calculator: Find the Right Wire Gauge for Your Project
the wire chart shows different sizes and lengths for each wire, which are labeled in red
the wire chart shows different sizes and lengths for each wire, which are labeled in red
an info sheet with different types of wires
an info sheet with different types of wires

Underrating wires, on the other hand, can lead to overheating, reduced lifespan, and even fire hazards. Therefore, it's crucial to select the correct wire size based on your specific application and environmental conditions.

Selecting the appropriate wire size is a critical step in any electrical installation. Using a wire size chart in mm² helps ensure that you're choosing a safe, efficient, and reliable wire for your needs. So, always consult the chart before starting your next project to ensure you're working with the right wire.