▲Wirig Diagram Hot
▲ ▲ ▼

Wire Size to Amps: MM2 to Amps Conversion Chart

By

Ever wondered how to determine the current-carrying capacity of a wire? It's more than just picking the thickest one! You need to know the wire size in square millimeters (mm²) and the current it needs to handle in amperes (A). Let's explore the relationship between these two, and how you can calculate one from the other.

Understanding this relationship is crucial for ensuring the safe and efficient operation of your electrical systems. Oversized wires are wasteful, while undersized ones can overheat and cause failure. So, let's dive right in.

The International Annealed Copper Standard

The current-carrying capacity of a wire is primarily determined by the International Annealed Copper Standard (IACS). This standard defines the electrical conductivity of pure copper at 20°C as 58 MS/m. Wires are then rated based on their conductivity relative to this standard.

What Size of Wire Do I Need for a 100 Amp Sub Panel?
What Size of Wire Do I Need for a 100 Amp Sub Panel?
AWG para mm²
AWG para mm²
the table shows how many different types of electrical equipment are available for each type of device
the table shows how many different types of electrical equipment are available for each type of device

IACS also provides a table of maximum allowable current for various wire sizes, assuming the wire operates at an ambient temperature of 30°C and has a gauge equal to its cross-sectional area in mm².

Understanding Wire Gauge

Wire gauge is a measure of its cross-sectional area. The most common standards are AWG (American Wire Gauge) and metric. For reference, here are some cross-sectional areas in mm² for common copper wire gauges:

MM2 to AWG - Wire Size Conversion Chart, Table, & Calculator [PDF]
MM2 to AWG - Wire Size Conversion Chart, Table, & Calculator [PDF]
the size and measurements for an amp speaker with different types of speakers in each section
the size and measurements for an amp speaker with different types of speakers in each section
Conversión AWG - mm2 500 a 1000
Conversión AWG - mm2 500 a 1000
  • AWG 18: 0.820 mm²
  • AWG 16: 1.290 mm²
  • AWG 14: 2.080 mm²
  • 4.00 mm²: 10.0 mm² (metric, for comparison)

Calculating Current from Wire Size

To calculate the maximum current a wire can carry based on its size, you can use the following formula, which is based on the IACS standard:

I = (A * k) / (R + L * R_a)

Where:

four different types of electrical wires are shown in this graphic above the image is labeled
four different types of electrical wires are shown in this graphic above the image is labeled
the wires and cable size chart for different types of electrical wire sizes are shown in red, blue, yellow, and orange
the wires and cable size chart for different types of electrical wire sizes are shown in red, blue, yellow, and orange
What is the Right Wire Size for 100-Amp Service Panel?
What is the Right Wire Size for 100-Amp Service Panel?
What Size Wire for 50 Amp 200 Feet (Wire Gauge, Electrical Load, Sizing)
What Size Wire for 50 Amp 200 Feet (Wire Gauge, Electrical Load, Sizing)
an info poster showing different types of wires
an info poster showing different types of wires
the cable size chart for an electrical device, with different colors and sizes to choose from
the cable size chart for an electrical device, with different colors and sizes to choose from
  • I: Maximum current in amperes (A)
  • A: Wire cross-sectional area in mm²
  • k: Conductivity constant (360 S/mm² for copper)
  • R: Resistivity (2.2 x 10^-8 Ωm for copper)
  • L: Length of the wire (usually, but not necessarily, in meters)
  • R_a: Ambient temperature rise (usually 30 K for electricity)

Plugging in the values, you get:

I = (A * 360) / (2.2 x 10^-8 * L + 30) * 10^-8

Calculating Wire Size from Current

For most applications, you'll know the current you need to carry. So, you'll need to find the wire size that can handle that current.

the different types of wires are shown in this diagram, which shows what they look like
the different types of wires are shown in this diagram, which shows what they look like
an electrical calculator with the text how to calculate cable size mm2 for 3 phase
an electrical calculator with the text how to calculate cable size mm2 for 3 phase
wiring diagrams for different types of wires
wiring diagrams for different types of wires

You can rearrange the formula above to solve for A:

A = I * (2.2 x 10^-8 * L + 30) / 360

Basics of Wire Material and Temperature

The calculations above assume copper wire operating at 30°C. If you're using a different material, you'll need to adjust the conductivity constant (k).

Moreover, if your application involves higher ambient temperatures or heat generation, you'll need to make adjustments to the calculation. The formula above provides a starting point, but always consult with an electrical engineer for specific applications.

Practical Examples

Let's look at a couple of examples to illustrate these calculations. Suppose you have a 10-meter length of wire.

  • Using AWG 14 (2.08 mm²) copper wire for a 10A circuit:

    Using the formula above, we get:

    A = 10 * (2.2 x 10^-8 * 10 + 30) / 360 = 2.08 mm²

  • Using a 1.5mm² copper wire for a 10-meter, 20A circuit:

    Rearranging the formula:

    I = 1.5 * (2.2 x 10^-8 * 10 + 30) / 360 = 20.2 A

So there you have it. Understanding the relationship between wire size and current can help you make informed decisions about your electrical system design. Always remember to factor in the specific conditions of your application, and consult with a professional when in doubt. Safe and efficient wiring practices ensure the longevity and integrity of your electrical systems.