100 Amp Sub Panel Wire Size Chart for 200 Feet
When considering a 100 amp sub panel for your home or business, selecting the right wire size is crucial for safety and efficiency. This guide will help you navigate the complexities of sub panel wire sizing for a 100 amp service, focusing on a 200 feet run. Remember, it's always recommended to consult with a professional electrician before making any wiring decisions.
Before we delve into the specifics, let's understand why wire size matters. The wire's gauge determines its current-carrying capacity. Using a larger gauge (smaller number) wire allows more current and accommodates greater distances. Conversely, a smaller gauge wire handles less current and should be used for shorter distances.
Understanding Wire Gauges and Ampacities
Wire gauges, ranging from 14 to 4/0, are measured using the American Wire Gauge (AWG) system. The higher the number, the smaller the wire's diameter. Ampacity, on the other hand, is the maximum amount of current a wire can carry safely. It's crucial to understand these terms as they're intertwined with your 100 amp sub panel's wire sizing.
A 100 amp sub panel requires a main feed wire (also known as the feeder) capable of carrying 100 amps of current, typically using a #1 AWG copper wire. However, #2 AWG is also acceptable in some scenarios. For a 200 feet run, we'll consider both options and explore the outcomes.
#1 AWG Copper Wire
A #1 AWG copper wire has an ampacity of 115 amps for a 200 feet run, assuming a 90°C (194°F) ambient temperature and rectangular(infofill) conduit with 125 volt, uninsulated conductors, according to NEC Table 310.16. This wire size is suitable and safe for a 100 amp sub panel up to 200 feet.
Here's an example of how you might use a #1 AWG copper wire in a 125-amp feeder circuit: #1 AWG THHN/THWN-2copper conductors in a 3/4" or 1" rigid metal conduit (RMC) or a 3/4" or 1" IMC (Interlocked Metal Conduit).
#2 AWG Copper Wire
A #2 AWG copper wire has an ampacity of 95 amps for a 200 feet run under the same conditions. While this option is acceptable according to NEC rules, it operates closer to its maximum capacity, leaving less room for safety margins and potential future expansions.
Using a #2 AWG copper wire in a 125-amp feeder circuit could look like this: #2 AWG THHN/THWN-2 copper conductors in a 1/2" or 3/4" RMC or IMC. However, it's essential to keep in mind that running #2 AWG for 200 feet reduces your safety margin, and it's generally recommended to stick with #1 AWG for better reliability and future-proofing.
Sizing Sub Panel Feeder Wires for Other Distances
While this guide focuses on a 200 feet run, it's helpful to know how to size wires for other distances as well. Here's a simple table for reference, based on NEC Table 310.16:
| Wire Size | Ampacity (200 ft) | Ampacity (150 ft) | Ampacity (100 ft) |
|---|---|---|---|
| #1 AWG | 115 amps | 130 amps | 140 amps |
| #2 AWG | 95 amps | 105 amps | 115 amps |
As you can see, as the distance decreases, the wire's ampacity increases, allowing for greater current-carrying capacity.
In planning your 100 amp sub panel wire sizing for a 200 feet run, it's crucial to consider safety, future expansion, and efficiency. While #2 AWG copper wire is acceptable, #1 AWG provides a better safety margin and allows for future growth. Always consult with a licensed electrician for personalized advice and peace of mind.