When working with electrical cable management, it's crucial to have the right tools for the job, including cable cleats of the correct size. In the UK, there are specific standards and regulations that govern the sizing and use of cable cleats to ensure safety and efficiency in your installation. Today, we'll delve into the intricacies of cable cleat size charts, helping you navigate UK standards and find the right cleats for your cables.

Firstly, understanding the UK's regulations is vital. The most relevant standards are BS EN 61534:2010 and BS 7671:2018 (The IET Wiring Regulations 18th Edition). These standards provide guidelines on the use of cable cleats, their sizing, and installation methods. Now, let's explore the world of cable cleat size charts and how to interpret them.

Understanding Cable Cleat Sizing

Cable cleats are sized based on the outer diameter of the cables they secure. The most common cable cleat sizes in the UK correspond to the following British Standard cable sizes: 1.5 mm², 2.5 mm², 4 mm², 6 mm², 10 mm², 16 mm², 25 mm², 35 mm², and 50 mm². It's essential to choose the right cleat size to prevent damage to the cables and ensure they remain secure during installation, operation, and maintenance.

Electrical Wire & Cable Sizes with Current Rating ⚡ Cheat Sheet for Safe Wiring Guide
Electrical Wire & Cable Sizes with Current Rating ⚡ Cheat Sheet for Safe Wiring Guide
758K views • 7.6K likes | Reel by Maa Khodal Electrician
758K views • 7.6K likes | Reel by Maa Khodal Electrician
table size chart for cable sizes
table size chart for cable sizes

Manufacturers provide cable cleat size charts to assist with selecting the appropriate cleats for specific cable diameters. The charts usually display cable sizes on one axis and corresponding cleat sizes on the other. By cross-referencing your cable's size with the chart, you can determine the suitable cleat size.

Reading Cable Cleat Size Charts

Here's a simplified example of a cable cleat size chart to illustrate how to read it:

Cable Gland Chart: A Guide for Electrical Design | Gurunath Tatphale posted on the topic | LinkedIn
Cable Gland Chart: A Guide for Electrical Design | Gurunath Tatphale posted on the topic | LinkedIn
PG16 Cable Gland Connector size chart
PG16 Cable Gland Connector size chart
Cable Cleat Installation guide
Cable Cleat Installation guide
Simplified Cable Cleat Size Chart
Cable Size (mm²)Cleat Size (mm)
1.516
2.516
416
619
1019
1625
2525
3535
5050

In this chart, for a 6 mm² cable, you'd select a 19 mm cleat. For larger cables, like 35 mm², you'd pick a 35 mm cleat. If the chart doesn't specify a cleat size for your cable, you might need to round up to the next available size or contact the manufacturer for guidance.

Factors Affecting Cleat Selection

Besides cable size, other factors can influence cleat selection. These include:

  • Cable Construction: armouring, sheathing, and other cable features may require different cleat sizes or types.
  • Installation Conditions: harsh environments, such as exposure to extreme temperatures, vibrations, orchemically hazardous areas, may necessitatespecial cleats.

Types of Cable Cleats

Knowing the different types of cable cleats is crucial to choosing the right one for your needs.

Cable Gland Size Chart for 4 Core Cables | PDF
Cable Gland Size Chart for 4 Core Cables | PDF
Cable Size Selection
Cable Size Selection
the cable size guide for cables and gland sizes is shown in this image
the cable size guide for cables and gland sizes is shown in this image
the wire cable size chart for different types of wires
the wire cable size chart for different types of wires
Cable Lug Size List
Cable Lug Size List
the table shows the number and type of electrical codes for various types of installations
the table shows the number and type of electrical codes for various types of installations

Some common types include:

  • Straight U-bends: Ideal for securing cables along straight runs.
  • Angle cleats: Suitable for securing cables at 90° bends or switchbacks. They support both vertical and horizontal cable runs.
  • Splayed cleats: Designed to accommodate multiple cables of different sizes in parallel.
  • Multi-branch cleats: Used to secure cables where they branch off in different directions.

Each type of cleat has its size chart, so it's essential to refer to the specific chart provided by the manufacturer.

In electrical cable management, having the right tools and knowledge is essential for a safe, efficient, and compliant installation. Familiarising yourself with cable cleat size charts and UK standards will help you select the appropriate cable cleats for your projects. Always cross-reference your cable's size, construction, and installation conditions with the manufacturer's recommendations to ensure you're using the right cleat for the job.

Cable Clamp Size Chart: Complete Guide 2025+ PDF
Cable Clamp Size Chart: Complete Guide 2025+ PDF
Cleat Wiring - EEE Made Easy
Cleat Wiring - EEE Made Easy
the size and measurements of cable sizes
the size and measurements of cable sizes
💬 Comments ↗ Share ★ Save
AD