What Size Entry Cable for 200 Amp Service

By

When planning for a 200 amp service, one crucial aspect that often goes unnoticed until the last minute is the choice of the entry cable. The right cable is essential to ensure the service's safety, efficiency, and compliance with electrical codes. So, what size entry cable do you need for a 200 amp service? Let's dive in to find out.

First, it's vital to understand that the ampacity of the service entrance cable must be equal to or greater than the service panels it's feeding. For a 200 amp service panel, you'll need a cable with an ampacity of 200 amps or higher. Now, let's explore the different types of cables suitable for this ampacity and the scenarios where you might use them.

Non-Metallic (NM) Cable

NM cable, also known as Romex, is a popular choice for residential applications due to its ease of installation and cost-effectiveness. However, for a 200 amp service, you might find that the available sizes are too small, as the maximum ampacity for NM cable is around 90 amps. This makes NM cable a less suitable option for 200 amp services.

How to Size Service-Entrance Conductors and Feeder Cables?
How to Size Service-Entrance Conductors and Feeder Cables?
What Size Wire for 30 Amps 200 Feet (Tips & Recommendation)
What Size Wire for 30 Amps 200 Feet (Tips & Recommendation)
What Size Wire for 30 Amps 200 Feet (Tips & Recommendation)
What Size Wire for 30 Amps 200 Feet (Tips & Recommendation)

Here's a quick overview of NM cable ampacity and gauge size for reference:

Upgrade electrical service from 100 amps to 200 amps
Upgrade electrical service from 100 amps to 200 amps
Grounding a 200 amp electrical service
Grounding a 200 amp electrical service
the size and length of wires are shown in this graphic above which wire sizes do you need to use?
the size and length of wires are shown in this graphic above which wire sizes do you need to use?
Gauge Ampacity (Amps)
14 15
12 20
10 30
8 45
6 65
4 90

Aluminum vs. Copper NM Cable

When dealing with NM cable, you'll find options in both copper and aluminum. While aluminum is less expensive, it has a higher resistance than copper, leading to more heating and potential electrical loss. Therefore, for a 200 amp service, using copper NM cable would be more recommended, even though it's costlier.

For most 200 amp services, you'll need to use multiple cables in parallel to achieve the required ampacity. This is because NM cable sizes above 4 AWG are often too large for standard electrical panels and can be difficult to work with. Always consult your local electrical code and an experienced electrician when considering this approach.

What Size Wire for 50 Amp 200 Feet (Wire Gauge, Electrical Load, Sizing)
What Size Wire for 50 Amp 200 Feet (Wire Gauge, Electrical Load, Sizing)
the industrial cable size chart is shown
the industrial cable size chart is shown
the size and measurements for cable sizes
the size and measurements for cable sizes
758K views • 7.6K likes | Reel by Maa Khodal Electrician
758K views • 7.6K likes | Reel by Maa Khodal Electrician
200 amp breaker disconnect
200 amp breaker disconnect
Cable Lug Size List
Cable Lug Size List

Stranded Metal Clad Cable

For larger ampacity needs, stranded metal clad cables (like THHN/THWN) are commonly used. These cables consist of individual insulated conductors stranded together and encased in a continuous metal armor. For a 200 amp service, you can use multiple smaller conductors to achieve the required ampacity.

For example, using three 6/3 THWN conductors would give you an ampacity of around 200 amps. Here's a table showing the ampacity of THWN at 90°C with a 60°F ambient temperature:

the different types of cable plugs and connectors for electrical devices with price tags
the different types of cable plugs and connectors for electrical devices with price tags
Gauge Ampacity (Amps)
14 15
12 20
10 30
8 45
6 70
4 105
3 140

Faraday Cage and Grounding

When using metal clad cables, ensure that they are properly grounded to maintain safety and comply with electrical codes. The metal armor should be connected to the service's ground electrode or grounding electrode conductor (GEC). Also, be aware of the Faraday cage effect, which can occur when too many parallel conductors are used without proper bonding and grounding.

To mitigate this issue, always bond multiple conductors together at both ends, and ensure that the bond connects to the service's grounding system. Consulting an experienced electrician can help you navigate these complexities and ensure your installation is safe and code-compliant.

In many cases, deciding on the right entry cable for a 200 amp service involves weighing factors such as cost, availability, and ease of installation. Copper THWN cables, while more expensive, may be a better choice due to their superior conducting performance and flexibility. Meanwhile, installing multiple smaller NM cables in parallel can be more cost-effective and easier to work with, but it may require more planning and consultation with an experienced electrician. Always prioritize safety and compliance with electrical codes when making your decision.