▲Wirig Diagram Hot
▲ ▲ ▼

Choosing Optimal Wire Size for 100 Amp Sub Panel at 100 Feet (200 Amp)

By

When it comes to extending your home's electrical capacity, installing a 100-amp sub panel 100 feet away from your main panel is a common yet complex task. It's crucial to understand the role of wire size to ensure safety, efficiency, and compliance with National Electrical Code (NEC) regulations. This guide will help you determine the appropriate wire size for your 100-amp sub panel, keeping your 200-amp main panel and your electrical system in sync.

Before diving into the wire sizes, let's clarify the terminology. The term "amp" refers to ampere, a unit of electrical current. The wire size, meanwhile, is determined by its American Wire Gauge (AWG) number. The lower the AWG number, the larger the wire diameter and its Current-carrying capacity (CCC).

Understanding Wire Size for Sub Panel Feeder

The feeder wire connects your main panel to your sub panel, carrying electrical current to power outlets, lights, and appliances. For a 100-amp sub panel, you need a wire with sufficient CCC to handle the load safely and efficiently.

Wire size for 100 amp basement sub-panel
Wire size for 100 amp basement sub-panel
Wire Size For 100 Amp Service 150 Feet
Wire Size For 100 Amp Service 150 Feet
What is the Right Wire Size for 100-Amp Service Panel?
What is the Right Wire Size for 100-Amp Service Panel?

As per NEC 2020, for a 100-amp circuit, the recommended.Common Trip Size (CTS) is 125% of the circuit's rating. In this case, the CTS would be 125 amps. This means you need a wire size that can handle 125 amps safely at 75°C (167°F).

100 Amp Sub Panel Wire Size: Copper vs Aluminum

You can choose between copper and aluminum wires for your sub panel feeder. Copper wires offer better conductivity and are less prone to corrosion but are more expensive. Aluminum wires, on the other hand, are affordable and lighter but have a lower CCC and are more susceptible to oxidation.

Sub Panel Wire Size Calculator – Accurate Wire Gauge & Load Sizing Tool
Sub Panel Wire Size Calculator – Accurate Wire Gauge & Load Sizing Tool
What wire type & size for sub-panel in a shed?
What wire type & size for sub-panel in a shed?
100 amp Attached Garage Sub Plan
100 amp Attached Garage Sub Plan

For a 100-amp panel, here are the recommended wire sizes for both materials according to their CCC:

Wire Size (AWG) Copper (CCC in Amps) Aluminum (CCC in Amps)
2 200 150
4 105 70
6 80 55
8 60 40

Recommended Wire Size for 100 Foot Distance

The voltage drop is another critical aspect to consider when choosing a wire size. Voltage drop increases with the length of the wire and the load. To minimize voltage drop, you need a wire with a sufficiently large diameter, especially for a 100-foot run.

For a 100-amp sub panel 100 feet away, a #4 AWG copper wire or a #2 AWG aluminum wire would be suitable, considering both their CCC and the distance. However, always consult with a licensed electrician or the local building department to ensure compliance with local codes and regulations.

What Size of Wire for 30 Amp?
What Size of Wire for 30 Amp?
an electrical panel with the words, 100 amp sub panel install and instructions on it
an electrical panel with the words, 100 amp sub panel install and instructions on it
What Size Wire for 50 Amps (A Handy Guide)
What Size Wire for 50 Amps (A Handy Guide)
What Size Wire for 50 Amp? Exact Gauge Guide for Safe & Code-Compliant Wiring
What Size Wire for 50 Amp? Exact Gauge Guide for Safe & Code-Compliant Wiring
How to Wire a Subpanel? Main Lug Installation for 120V/240V
How to Wire a Subpanel? Main Lug Installation for 120V/240V
Upgrade electrical service from 100 amps to 200 amps
Upgrade electrical service from 100 amps to 200 amps

Running a 100 Amp Sub Panel Wire: Factors to Consider

Planning your wire run carefully is as important as choosing the right wire size. The following factors can impact your wire choice and installation:

Conduit Size: The conduit holds and protects your electrical wires. Its size is determined by the number and size of the wires it contains. Always choose a conduit that can accommodate your feeder wire and any future branch circuit wires.

Route and Installation: The route you take to run your feeder wire can affect its lifespan and efficiency. Keep your wire run as short as possible and avoid bends and sharp turns. Also, ensure proper support and strain relief to prevent damage due to movement or vibration.

Installing A Electrical Sub Panel
Installing A Electrical Sub Panel
What Wire Size For 100 Amp Sub Panel That's 200 Feet Away?
What Wire Size For 100 Amp Sub Panel That's 200 Feet Away?
Installing 100 Amp Service Wire To Work Shop
Installing 100 Amp Service Wire To Work Shop

Conduit Fill Calculations

When choosing a conduit, it's essential to know how many wires and of what size they can accommodate. The fill calculations consider the diameter of the wire and conduit to determine the maximum allowable wire fill. Always consult the NEC or a professional electrician for accurate conduit fill calculations.

Finally, always prioritize safety when working with electrical wires. Ensure you follow local building codes, obtain the necessary permits, and hire a licensed electrician if you're not familiar with electrical work. Proper planning and installations not only protect your home and loved ones but also ensure optimal performance from your sub panel.